Products

ARI-8500

High Frequency Digital Radiography X-ray System

ARI-8500 high frequency Digital Radiography system (DR)

Main parameters

Model

ARI-8500C

Power output

55kw

Frequency

60khz

Tube current

100~500ma

Tube voltage

40~150kv

MAS

0.1~630mas

Automatic exposure control time

5ms

Focus size

0.6/1.2

Detector type

Flat panel detector

Vision size

17"x17"

Pixel size

143um

Shortest imaging time

less than 12s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Specification:

1. X-ray Generator

Power supply is 380/400 V +/-%10 ve 50 Hz +/-%3

H.F. value is 60KHz

X-Ray Generator power is 65 kW

kV40150kV by steps

mA10650mA by steps

mAs0.1630mAs by steps

time:0.001-2 sec by steps

AEC with 3 chambers

2. X-ray tube

X-Ray tube have safety control for over heating and overloading

focus: 0.6mm* 1.2mm

anode heat capacity: 300kHU

housing heat capacity: 1250kHU

3. Collimator

Collimator have 0.1-0.2mm A1 filters. Filter can be selected as manually according to selected APR.

Collimator have visible light

Collimator have a timer

Collimator have magnetically selected A1 filter system

4. Flat panel detector

A-Si and Csi FPD

Detector size43*43cm

DQE 65%

Matrix 2880*2880,14bit, gray scale is 16384 steps

Pixel size is 150 micron

DAP is adapted with software and show measured dose values on the screen and film .

3 chamber AEC.

Final image can be coming to the monitor, max in 9 seconds after exposure.

Detector spatial resolution is 4.3 lp/mm

Detector move manually and be controlled from detector side and tube side.

Grid 80 line /cm, 10:1  

5. DR Control Console

DR console process the images

FULL DICOM compatibility

Patient datas are controllable from this software.

Multi-Image Display

Zoom/Pan

Magnifying glass

Black and white inversion(positive-Negative image). 

Up and down, right and left rotation.

Window/Level

Edge enhancement

Annotation

L/R labels

Measurement, angles

Multitasking

Soft tissue and bone tissue can be shown at the same time (As Diamondview or Unique or Tissue Equalisation).

CD / DVD room to create Patient CD with miniviewer.

More than one image can be shown on the same monitor and burn in the CD/DVD

6. U-ARM STAND

U-Arm can move motorized in all directions.(only detector move manual)

All movement can be controlled from tube side and detector side.

U –arm can move a 120 cm in vertical position as motorized.

U-arm can rotate -30˚+120˚ as motorized

Detector can rotate -45˚+45˚ as manual.

SID 100 cm to 180 cm variable, as motorized

 

Copyright © 2001-2017 ARI Medical Equipment Co., Ltd. - ARI Technology Group. All rights reserved