Products

AR-M20B

High Frequency Mobile Digital C-arm System

I. Application

Orthopedics: osteopathy, displaces, nailing.

Surgery: removing foreign body, implanting pace maker, interventional therapy, partial radiography, local photography, and other work.

II. Features

1. With a compact appearance, and easy to operate.  

2. Unique base electric auxiliary support arm design, it's more security for using.   

3. A unique hand-held controller design, convenient to operate.

4. With a high-quality knockdown X-ray generator to reduce radiation.

5. With the Perspective KV, MA automatically track fluoroscopy to make the image brightness and clearness optimum.

6. Toshiba image intensifier three view, the quality is stable and reliable, a good image clarity.

7. Image acquisition and processing workstation

Registration: registration, medical records, Worklist

Collection: Start collection; prepare video, reset, horizontal mirror, vertical mirror, window adjustment, magnifying glass, negative image

Open silhouette, edge enhancement, recursive noise reduction

Processing; four windows, nine windows, sharpening, horizontal mirror, vertical mirror, text annotation, length measurement report: save, preview, expert template

Dicom features: Dicom browsing, web service  

Automatically track fluoroscopy to make the image brightness and clearness optimum; Installation of dense grain grids, to further enhance image sharpness    

8. Automatic dynamic motion detection when fluoroscopy to avoid movement-related blurring, no silhouette

III. Configuration

1, New (with electric auxiliary support arm) C-arm host     1 set

2, High-frequency high-voltage X-ray generator and high-frequency inverter power supply(5KW40KHZ120KV)                         1  set

3, Toshiba 9-inch image intensifier three view9inch/ 6 inch / 4.5 inch1 set  

4, Imports of super-low-light digital camera 1024x1024           1 set    

5, CCU in the high-definition progressive output control system    1 set

6, Dense grain grids                                 1 set     

7, Electric adjustable beam collimator                  1 set     

8, 19 inch LCD display                               2 sets     

9, hand-held controller                               2 sets    

10, Foot switch for exposure                          2 sets    

11, Red-cross positioned                             1 set    

10, Digital work station with printer                    1 set

IV. Technical Specifications

PARAMETER

SPECIFICATION

Fluoroscopic

Capacity

Photography Max rated capacity

5KW

Fluoroscopic ax rated capacity

Tube Current 4mA, Tube Voltage 120kV

Automatic Fluoroscopy

Tube Voltage: 40kV120kV adjust automatically

Tube Current: 0.3mA4mA adjust automatically

Manual Fluoroscopy

Tube Voltage: 40kV120kV Continuous

Tube Current: 0.3mA4mA Continuous

Pulse Fluoroscopy

Tube Voltage:40kV120kV Continuous

Tube Current: 0.3mA8mA Continuous            

(1,) intelligent frequency conversion technology is more advanced

(2,) improves the quality of single-frame images and reduces the amount of radiation

(3,) the tube is protected, continuous working time is extended

(4,) frequency: 0.5 ~ 8pps (frame / s) pulse length

Photography Tube Voltage and mA

40 kV~120 kV  20-100mA  1.0mAs180mAs

Plate holder Size

200mm×250mm(8″×10) or 

250mm×300mm(10″×12)

X-ray Tube

X-ray Tube Special for High Frequency

Fixed anode Dual-focus, 0.3/1.5,

Inverter Frequency: 40KHz

Anode capacity: 35KJ (47KHU)           

Tube thermal capacity: 650kJ867kHu 

Video

System

Image Intensifier

Image Intensifier made by TOSHIBA (9)

Three view9inch/ 6 inch / 4.5 inch

E5764SD-P3 

Image definition indicators 12 bit  

CCD Video camera

1 Mega Ultra low-light CCD camera

Monitor

19LCD monitor *2

Resolution 1280*1024,

CCU(central control)

Recursive Filter: K=8, 8 images storage, image upright, image overturn, positive & negative imageLIH(last image freeze, and OSD (monitor display)

Structural performance

Directive wheel 

±90°revolution, can freely change the moving direction of the unit.

C-arm 

Forward and Backward Movement: 200mm

Up and down:400mm

Revolution around Horizontal Axis: ±180°

Revolution around Vertical Axis: ±15°

Focus screen distance: 960mm

C-arm opening: 740mm

C-arm arm depth: 640mm                     Slide along the orbit: 120°(+90°~ -30°)


Copyright © 2001-2024 ARI Medical Technology Co., Ltd. - ARI Technology Group Co., Ltd. All Rights Reserved.