Search
Close this search box.

Products

Features

-10.4” high-resolution color touch screen

-User friendly design interface

-Tidal volume 5~1500 ml

-Up to 5 flow tubes for 3 gases

-PSU material of breathing circuit

-By-pass Tech for soda lime canister,Soda lime can be replaced during surgery

-All ventilation modes to satisfy neonate, pediatric and adult patients

-Integrated breathing circuit with built-in heater

-Highly visible ACGO

Technical Specifications

PARAMETER SPECIFICATION
Screen 10.4” high-resolution color touch screen, 1024×768 pixels
Gas supply O2, N2O, AIR
Flow Meter O2:   0–10L/min

N20:   0–10L/min

Air:   0–10L/min

Selectatec bar Dual positions
Mechanical Flowmeter 5 flow tubes for 3 gases
Rapid Oxygen Flow 25–75L/min
Waveforms Up to 3 waveforms, user configurable
O2 -N2O Link System Type: Gear wheel linkage;

Range: O2 concentration not lower than 25%.

Low Oxygen Pressure Alarm There will be sound alarm when the oxygen pressure < 0.2MPa
Respiratory Circuit Working mode: all-close, semi-close, semi-open;

APL: 1-70 cmH2O

Respiratory Bellows Bellows for adults, tidal volume range:0–1500ml;

Bellows for children, tidal volume range:0-300ml.

Anyone can be chosen for application as required by the customer

VENTILATOR
Ventilation Mode Manual, VCV, PCV, SIMV-VC, SIMV- PC, PSV, Standby, ACGO Optional modes: PRVC, HLM
Ventilation Function PEEP, SIGH, IP, IRV, standby
Spirometry loop P-V, P-F, F-V, reference Loop
Ventilation Parameters Tidal volume           5~1500ml

Rate                  4~100bpm

SIMV rate                    4~40bpm

I:E                   4:1~1:8

Inspiratory trigger pressure    OFF, PEEP-20 ~ PEEP-1cmH2O

PEEP                  0~70cmH2O

Pressure limitation      10~100cmH2O

Pplatform              -20~120cmH2O

Pressure control        5~70cmH2O

Pressure slope         0~2 s

Parameters for Ventilation

Monitoring

Expired tidal volume, Inhale tidal volume, Minute ventilation volume, IPPV rate, SIMV rate, total respiratory rate, autonomous breathing rate, I/E, peak pressure of airway, average pressure, PEEP, inspiratory trigger pressure, Inspiratory platform, oxygen concentration, battery capacity, pressure-time waveform, flow-rate-time waveform, volume-time waveform, flow-volume loop, pressure-volume loop
Sustained High-pressure

Alarm

Paw greater than alarm limit for continuous high airway pressure for >15s
Auxiliary power outlets 3
Wheels Four wheels(155mm) with 2 or 4 separate brakes
Drawers 2
Vaporizer It has the function of automatic compensation based on pressure, temperature, and flow rate.

The regulation range of evaporator concentration is 0-6vol%. Selectatec®, With interlocking function.

Vaporizer types: Halothane, Enflurane, Isoflurane and Sevoflurane.

O2 cell Standard
Built-in Heater Standard
By-pass Standard
ACGO Standard
Li-ion Battery Standard 1 battery, 4800mAh;

Optional 2 batteries.

Spare Cylinder yoke Optional (O2, N2O)
AGSS Optional
Gas monitor module Optional (ETCO2, AG)
Patient monitor Optional
Suction Device Optional
Standard: Main unit, O2 cell, Built-in Li-on battery, Disposable adult anesthesia breathing circuit, O2/N2O/Air gas pipelines, Hospital O2/N2O/Air joints
Options: Vaporizer (CE certified Vaporizer of the same brand), Patient monitor, ETCO2, Suction module, Pediatric/Neonate anesthesia breathing circuit, Spare cylinder yoke (O2, N2O), AGSS, Gas monitor module (ETCO2, AG), etc.