Search
Close this search box.

Products

Features

  1. 4-inch Color LCD Display
  2. The pupil is simulated by LCD display and has light reflex, which can simulate the pupil’s shrinkage, normal and dilated state; the pupil dilation and light reflex disappear in the rescue state, and the pupil shrinkage and light reflex are restored after the rescue is successful
  3. Evaluation process: In addition to CPR operation, five operations can be performed: consciousness judgment, emergency call, pulse check, breathing check, and oral foreign body removal
  4. New electronic wireless remote control function: The teacher can use the remote control to remotely control CPR start, stop, reset, volume, mode selection, pupil changes, carotid artery pulsation, printer and other functions
  5. The key operation adopts fault-tolerant technology, and there is a voice prompt for key operation errors to avoid user misoperation
  6. Added insufficient chest rebound detection, and there is a voice prompt for the user
  7. The upper limb joints of the simulated person can move freely. (Pronation, supination, extension and contraction, flexion and extension, internal rotation, external rotation; wrist and elbow joints can be flexed and extended, extension and contraction; shoulder joints can be flexed and extended and circumferential rotation), and patient handling can be practiced

Simulated Vital Signs

  1. In the initial state; the carotid artery has no pulsation, the simulated pupil is dilated, and the other party’s reflex disappears
  2. During the compression process; the simulated carotid artery passively pulsates, and the pulsation frequency is consistent with the compression frequency. The simulated heart swell pulsation is consistent with the compression frequency
  3. After the rescue is successful; the carotid artery pulsates autonomously, the simulated pupil shrinks, and the light reflex is restored
  4. The LCD pupil zoom and carotid artery pulsation can be turned on and off
  5. Three operation modes: CPR training, simulation assessment and actual combat assessment can be performed
  • 1) CPR training: Compression and blowing can be performed
  • 2) Simulation assessment: Within the specified time, according to the 2020 international cardiopulmonary resuscitation standards, the ratio of compression and blowing is 30:2, and 5 cycles of operation are completed, and the statistical data is used to make money. The system has an automatic scoring system
  • 3) Actual combat assessment: Within the set time range, according to the 2020 international cardiopulmonary resuscitation standards, complete the pre-set assessment standards (teachers can set the operation time range, number of cycles, etc.); statistical data prints the results, and the system has an automatic scoring system

CPR Display

  1. Wireless connection between controller and simulator
  2. Electronic monitoring: Electronic monitoring of compression and blowing, displaying the correct and incorrect times of artificial respiration and cardiac compression
  3. Voice prompts: Chinese voice prompts throughout training and assessment, voice can be turned on and off, and the volume can be adjusted
  4. The operation time can be set by yourself in seconds
  5. The number of cycles can be set by yourself
  6. When performing manual chest compression:
  • Dynamic barcode indicator light displays compression depth: Correct compression depth (5-6cm area) is displayed by the green barcode light, insufficient compression depth is displayed by the yellow barcode indicator light, and excessive compression depth is displayed by the red barcode indicator light, dynamically feedback CPR compression depth; real-time synchronous display of compression force and depth (reflected by rectangle or ripple graph)
  • LCD count and frequency display: detailed record of the number of incorrect compressions and specific reasons (excessive compression force, too little compression force, wrong compression position, too fast or too slow compression frequency, etc.), correct number
  • Language prompts: Chinese voice prompts, detailed prompts of the specific reasons for incorrect compressions, so that trainers can correct them in time
  • Red heart display simulates heart beats
  1. During artificial mouth-to-mouth respiration (blowing):
  • Dynamic barcode indicator light displays the tidal volume blown in: correct blowing (500ml-1000ml) is displayed by the green barcode indicator light, too little blowing is displayed by the yellow barcode indicator light, and too much blowing is displayed by the red barcode indicator light, and the tidal volume blown in is dynamically fed back; the size of the tidal volume blown in is displayed synchronously in real time (reflected by a rectangle or ripple graph)
  • LCD counting display: Detailed record of the number of blowing errors and specific reasons (according to excessive blowing volume, blowing into the stomach, too little blowing force), the number of correct blowing
  • Standard airway opening can be performed: airway opening indicator light display

Power Supply

It can be used with a plug-in or with a lithium battery without power supply. It uses a 110V/220V power supply, and the output power supply is 12V after being stabilized by a stabilizer. After the lithium battery is fully charged, it can work for 8 hours in the field without power supply to ensure normal operation without an external power supply

Printer Function

  1. Short print (data transcript) and long print (blow and press waveform) can be selected
  2. The transcript covers operation mode, consciousness judgment, emergency call, pulse check, breathing check, foreign body removal, operation frequency, compression and blowing ratio, number of cycles, number of compressions and blows in each cycle, number of correct/incorrect compressions, reasons for incorrect compressions, number of correct/incorrect blows, reasons for incorrect blows, setting time, operation time and assessment

Standard Configuration

Advanced cardiopulmonary resuscitation simulator —–1PC

Advanced touch-screen color LCD controller —–1PC

Luxurious hand-pull and push human body hard plastic box —–1PC

Resuscitation operation pad —–1PC

Disposable disinfection mask (50 sheets/box) —–1 BOX

Wireless remote controller —–1PC

Replaceable face skin —–1PC

Replaceable lung sac devices —–5PCS

Thermal printing paper —–2 ROLLS

First aid operation manual —–1PC