12.1-inch TFT color screen Folding up to 90 degree
The monitor of light weight and space-saving.
It can meet the need of whole stages of labor (including antepartum and intrapartum monitoring for fetus and mother)
It also can be connected to the obstetrical central station

Features

Lightweight, space-saving, easy operations
Interface of parameters of FHR, TOCO and Fetal Movement with display
Li-Ion battery, 2200mAh/14.8V Maximum 4 hours of continuous monitoring
Alarm system
12.1-inch TFT color screen Folding up to 90 degree
DSP technology, real time identify and measurement for FHR, accurate and reliable results
Special high sensitive transducer
42 hours data storage which can be playback and printed
Low ultrasound power, safe to fetus
Wide range of applying voltage(100-240V)
Auto FM testing

Specification

Fetal Heart Rate (FHR)
Parameters: FHR1, FHR2 (optional)
Measurement range: 50 – 240 bpm
Accuracy: ±2 bpm;
Sweep speed: X1, X2, X4, X8

Transducer
9 crystals, pulsed Doppler, high sensitivity
Frequency: 1.0MHz
Probe: wired

Uterine Activity (TOCO)
Measurement range: 0 – 100
TOCO baseline: 0, 5, 10, 15, 20 (selectable)

Maternal ECG/HR (MECG) (optional)
Lead type: 5-lead
Lead selection: RA, LA, RL, LL, V
HR measurement range: 15 bpm – 300 bpm
Accuracy: ±1 bpm or ±1 %, whichever is greater

Respiration Rate (optional)
RESP Rate range: 7 rpm – 120 rpm
Accuracy: ±2 rpm/min or ±2 % reading, whichever is greater

Maternal Non-invasive Blood Pressure (NIBP) (optional)
Method: Automatic Oscillometric
Parameters: SYS/DIA/MAP
Operating modes: Manual/Auto
Auto measure intervals: 3/5/10/20/30/60/90/120/240 minutes
Units: mmHg/kPa
Cuff pressure range: 0 mmHg – 300 mmHg (0 kPa – 40.0 kPa)
Measurement and alarm range:
SYS: 50 mmHg – 240 mmHg (6.7 kPa – 32.0 kPa)
MAP: 25 mmHg – 200 mmHg (3.4 kPa – 26.6 kPa)
DIA: 15 mmHg – 180 mmHg (2.0 kPa – 24.0 kPa)
Accuracy: Max. Mean Error: ±3 mmHg (±0.4 kPa) or ±2 of reading
Over-pressure protection: Yes

Maternal SpO2 (optional)
Measurement range: 70 – 99 %
Accuracy: ±3 %
PR range: 30 – 240 bpm
Accuracy: ±2 bpm/min or ±5 % reading, whichever is greater

Temperature (optional)
TEMP range: 0 – 50c°C
Resolution: ±0.1°C

Weight & Dimensions
Net Weight: 3.5kg
Dimensions: 350(L) * 320(W) * 85(H) mm

Standard Accessories
FHR.TOCO, FM Transducer
2 pcs of printer paper.
One power cable
Two bandages /three bandage (twin optional)
Second one transducer(optional)

Remark
3 Para (fetal monitor): FHR, TOCO, FM
6 Para (fetal/maternal monitor): FHR, TOCO, FM, MHR, SPO2, NIBP
9 Para (fetal/maternal monitor): FHR, TOCO, FM, MHR, SPO2, NIBP, ECG, RR, TEMP

Options
Twins Probe, Fetus Waker, Touch Screen, Trolley, Wall Bracket