Search
Close this search box.

Products

Technical Specifications

PARAMETER SPECIFICATION
Main Body High-strength engineering plastic rack, light, beautiful and corrosion resistant
Scope of Application Adult, child
Gas Source O2, N2O, Air: 0.28–0.6MPa.
Flow Meter O2: 0.05–1.0L/min; 1.1–10L/min

N20: 0.05–1.0L/min; 1.1–10L/min

Air: 0.05–10L/min

O2, N2O Linkage and N2O Stopper When using nitrous oxide, oxygen concentration>25%;

When the oxygen pressure < 0.2MPa, the flow of nitrous oxide would be cut off.

Rapid Oxygen Flow 25–75L/min
Low Oxygen Pressure Alarm There will be sound alarm when the oxygen pressure < 0.2MPa
Vaporizer It has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0-5vol%.

Among Halothane, Enflurane, Isoflurane and Sevoflurane, two can be chosen for application as required by the customer. And vaporizers that are imported with original packaging are also available.

Respiratory Circuit Working mode: all-close, semi-close, semi-open;

APL: ≤12.5kPa

Respiratory Bellows Bellows for adults, tidal volume range:0–1500ml;

Bellows for children, tidal volume range:0-300ml.

Anyone can be chosen for application as required by the customer

VENTILATOR
Display Mode High-definition 10.4” TFT color LCD screen display
Ventilation Mode VCV, PCV, SIMV, MANUAL
Ventilation Function PEEP, SIGH, IP, IRV, standby
Ventilation Parameters Tidal volume           20~1600ml

Rate                  2~99bpm

SIMV rate                    2~20bpm

I:E                   4:1~1:8

Inspiratory trigger pressure    -10~20cmH2O

PEEP                  2~20cmH2O

Pressure limitation      5~60cmH2O

SIGH         1.5 times the inspiratory time, 60~120 adjustable

Inspiratory platform      0~50%

Pressure control        3~50cmH2O

Pressure slope         1~10 gear

Parameters for Ventilation

Monitoring

Expired tidal volume, Inhale tidal volume, Minute ventilation volume, IPPV rate, SIMV rate, total respiratory rate, autonomous breathing rate, I/E, peak pressure of airway, average pressure, PEEP, inspiratory trigger pressure, Inspiratory platform, oxygen concentration, battery capacity, pressure-time waveform, flow-rate-time waveform, flow-volume loop, pressure-volume loop
SECURITY ALARM SYSTEM
Oxygen Concentration Alarm Upper limit setting range   21%–99%;

Low limit setting range     18%–80%

Airway Pressure Alarm Upper limit setting range   5–60cmH2O;

Low limit setting range     0–50cmH2O.

Minute Ventilation Volume Alarm Upper limit setting range   1–20L/min;

Low limit setting range     0–19L/min.

Respiratory Rate Upper limit setting range   10–99bPm

Low limit setting range     0–50bPm

Tidal Voulme Upper limit setting range   10–1500ml

Low limit setting range     0–1400ml

Sustained High-pressure

Alarm

It will give alarm when stress have consistently been higher than

25 cmH2O

Suffocation Alarm Power alarm, Battery voltage alarm, Intubation off alarm
Power AC 220V, 50Hz, UPS, Storage battery
Manipulators
(End-expiratory CO2 monitoring)
(Specific interface of waste anesthesia gas)
*Note: Items within brackets are optional.