Whole blood, Serum, Plasma, Dialysate, CSF
BG-800 (pH / pCO₂ / pO₂ / K⁺ / Na+ / CI- / Ca²⁺ / Hct)
BG-800A (pH / pCO₂ / pO₂ / Hct)
Working temperature:15℃~30℃
Storage environment:5℃~45℃
Power supply:100-240V~±10,50/60±1Hz
Dimension (Length*width*Height) 420mm×623mm×410mm
Weight: 18KG
1.Intuitive Touch Screen
–High resolution 10.4 ’’ touch screen
–User-friendly operation interface
–Parameter area prodes analyzer status at a glance
–Online operation and self-diagnostic tutorials
2.Infrared human-detector
3.Flexible and simple calibrants cartridge
–High and low volume testing cartridge can be chosen (300,200,150,100,50)
–30 days available on board
–Stored ar room temperature
–All-in-one design without extra consumables Cartridge expiration alarm and residue information
4.Easy to Use
–The sample adaptor is suitable for both syringe and capillary samples
–The sample probe’s wiper provides convenience, sample integrity and user safety
5.Rich data management
–RS-232 interface
–LIS connection under HL7 protocol
–Data backup with USB port
–Data Storage: >10000
6.Reliable and convenient measurement unit
–Capillary sample volume only 50μL
–Whole blood volume only 95μL
–Muti-combination parameters
–Self-made long life maintenance free electrodes
–Maximum 90s result from aspiration, less than 120s from sample to sample
–Long-lasting fluid system
–Preheats reagents and sample
7.Input Parameter
–Patient temperature
–Hemoglobin
–FiO₂
–B.P.
8.Characteristic
–Analysis Time: <90s
–Sample Volume: 95μL Whole blood, 50μL Capillary blood
–Calibration: Automatic, 1 point and 2 point calibration
–Battery: Nickel-matal hydride battery, 3.0Ah
Analyte | Measuring range | Unit |
Hydrogen ion activity(pH) | 6.000-9.000 | pH scale |
Carbon dioxide | 0.667-26.67 | KPa |
Partial pressure(pCO₂) | 5.0-200.0 | mmHg |
Oxygen partial pressure (pO₂) | 0-106.7 | KPa |
0-800.0 | mmHg | |
Potassium ion( K⁺) | 0.50-10.00 | mmol/L |
Sodiumion ( Na+) | 50.0-200.0 | mmol/L |
Chloride ion ( Cl-) | 20.0-200.0 | mmol/L |
Ionized calcium( Ca²⁺) | 0.10-5.00 | mmol/L |
Hct | 12.0-65.0 | % |
B.P. | 500-800 | mmHg |
Item | Parameters |
pH(TC) | pH temperature corrected |
pCO₂(TC) | pCO₂ temperature corrected |
pO₂(TC) | pO₂ temperature corrected |
TCO₂ | 0-50mmol/L |
HCO3- | 0-50mmol/L |
Be b | -25.0 – 25mmol/L |
Be ecf | -25.0 – 25mmol/L |
SBC | 0-50mmol/L |
sO₂% | 40 – 100.0% |
Ca²⁺(7.4) | Lionized calcium “normalized” to pH 7.4 |
TCa | Total calcium content |
AG | Anion gap |
RI | 0.0 – 70.0 |
AaDO₂ | 0 – 700mmHg |
O₂SAT | Oxygen Saturation |
tHb(c) | Hemoglobin (Calculated) |
Copyright © 2001-2025 ARI Medical Technology Co., Ltd. - ARI Group. All Rights Reserved.