-No electricity will be needed, only manual operation
-Module rack with polyester medical material, high strength and light weight.
-Superior thin spray technology, delicate color, beautiful and durable.
-High precious vaporizer, Halothane, Enflurane, Isoflurane and Sevoflurane could be choosen freely
-Main unit are only 2Kg (w/o vaporizer), light weight and easy to move
-With a dedicated handle, could move by hand-pull.
-Two gas sources: O2, N2O, suitable for more patient type
-Classical CO2 circle absorber with 1 canister, low resistance, minimum gas leakage, 60cmH2O peak pressure solution.
-Ventilator (Optional): TH-1, TH-1A
-3 types of Small Vaporizers and 4 types of Big Vaporizers for choice.
PARAMETER | SPECIFICATION |
Ventilation mode | Closed, Semi-closed, Semi-open |
Application | 2-100KG animals |
Gas source | O2, N2O 0.25Mpa~0.65Mpa |
Two tube (O2, N2O) | Scope,0—10L/min.With linkage device,O2 concentration not low than 25% |
O2 flush | more than 25L/min |
Respiratory mode | Manual, Oxygen |
TV | 50~2000mL |
I:E | according to the doctor operation |
BPM | according to the doctor operation |
APL Valve pressure | 0.5-6KPa |
Monitoring | Airway pressure, respiratory mode |
Three Gauges | one for O2, one for N2O, one for airway pressure |
Environment Requirement | |
Temperature | Operation: 18~36 ºC |
Storage: -20~55 ºC | |
Humidifier | Operation:45%~75% |
Storage:≤93% | |
Atmospheric pressure | Operation:0.95~1.05 bar |
Storage: 500hPa~1060hPa | |
Altitude | Operation:500 to 800mmHg (3565~-440m) |
Storage:375 to 800mmHg (5860~-440m) |
Two Anesthesia Ventilators (Optional)
– Independent Anesthesia Ventilator, with IPPV and Manual mode
– With necessary monitoring and alarm function, to make sure the operation safety
– Gas supply: O2, or Air
– With international connector, can be matched with various brands of anesthesia machines
TH-1A Parameter
– Respiration mode: IPPV, SIMV, Manual
– Respiratory frequency: 1 to 65BPM
– Display: 5.5´ SNT screen
– I:E ratio: 8:1~1:8
– Waveform: P-t, V-t
– Tidal volume: 50ml~1600ml
– Monitor Parameters: Tidal volume; Minute Ventilation; Peak
TH-1 Parameter
– Control method: Gas driving electronic controlled
– Breath frequency: 1~90BPM
– Display: High light LED display
– I:E ratio: 4:1~1:6
– Respiration mode: IPPV, Manual
– Tidal volume: 50~1500ml
– Monitor Parameters: Tidal volume; Minute Ventilation; Breath Frequency; Airway Pressure
– Independent Anesthesia Ventilator, with IPPV and Manual mode
– With necessary monitoring and alarm function, to make sure the operation safety
– Gas supply: O2, or Air
– With international connector, can be matched with various brands of anesthesia machines
Copyright © 2001-2025 ARI Medical Technology Co., Ltd. - ARI Group. All Rights Reserved.