Feature

-No electricity will be needed, only manual operation

-Module rack with polyester medical material, high strength and light weight.

-Superior thin spray technology, delicate color, beautiful and durable.

-High precious vaporizer, Halothane, Enflurane, Isoflurane and Sevoflurane could be choosen freely

-Main unit are only 2Kg (w/o vaporizer), light weight and easy to move

-With a dedicated handle, could move by hand-pull.

-Two gas sources: O2, N2O, suitable for more patient type

-Classical CO2 circle absorber with 1 canister, low resistance, minimum gas leakage, 60cmH2O peak pressure solution.

-Ventilator (Optional): TH-1, TH-1A

-3 types of Small Vaporizers and 4 types of Big Vaporizers for choice.

Technical Specifications

PARAMETER SPECIFICATION
Ventilation mode Closed, Semi-closed, Semi-open
Application 2-100KG animals
Gas source O2, N2O   0.25Mpa~0.65Mpa
Two tube (O2, N2O) Scope,0—10L/min.With linkage device,O2 concentration not low than 25%
O2 flush more than 25L/min
Respiratory mode Manual, Oxygen
TV 50~2000mL
I:E according to the doctor operation
BPM according to the doctor operation
APL Valve pressure 0.5-6KPa
Monitoring Airway pressure, respiratory mode
Three Gauges one for O2, one for N2O, one for airway pressure
Environment Requirement
Temperature Operation: 18~36 ºC
Storage: -20~55 ºC
Humidifier Operation:45%~75%
Storage:≤93%
Atmospheric pressure Operation:0.95~1.05 bar
Storage: 500hPa~1060hPa
Altitude Operation:500 to 800mmHg (3565~-440m)
Storage:375 to 800mmHg (5860~-440m)

 

Anesthesia Ventilators (Optional)

Two Anesthesia Ventilators (Optional)

– Independent Anesthesia Ventilator, with IPPV and Manual mode

– With necessary monitoring and alarm function, to make sure the operation safety

– Gas supply: O2, or Air

– With international connector, can be matched with various brands of anesthesia machines

 

TH-1A Parameter

– Respiration mode: IPPV, SIMV, Manual

– Respiratory frequency: 1 to 65BPM

– Display: 5.5´ SNT screen

– I:E ratio: 8:1~1:8

– Waveform: P-t, V-t

– Tidal volume: 50ml~1600ml

– Monitor Parameters: Tidal volume; Minute Ventilation; Peak

 

TH-1 Parameter

– Control method: Gas driving electronic controlled

– Breath frequency: 1~90BPM

– Display: High light LED display

– I:E ratio: 4:1~1:6

– Respiration mode: IPPV, Manual

– Tidal volume: 50~1500ml

– Monitor Parameters: Tidal volume; Minute Ventilation; Breath Frequency; Airway Pressure

– Independent Anesthesia Ventilator, with IPPV and Manual mode

– With necessary monitoring and alarm function, to make sure the operation safety

– Gas supply: O2, or Air

– With international connector, can be matched with various brands of anesthesia machines