Products
-
- Operating Theatre Equipment
- OB/GYN Equipment
- Diagnostic Equipment
- Sterilizer (Autoclave)
- X-ray Series
- Laboratory Equipment
- Biological Microscope
- Spectrophotometer
- High Speed Centrifuge
- Low Speed Centrifuge
- High Speed Freeze Centrifuge
- Low Speed Freeze Centrifuge
- Special Centrifuge
- Thermostatic Bath
- Laboratory Shaker
- Laboratory Mixer
- Water Distiller
- Magnetic and Electric Stirrer
- Laboratory Incubator
- Dry Oven
- PH Meter
- Biological Safety Cabinet
- Clean Workbench
- Water Purifier
- Ultrasonic Cleaner
- Pipette
- Microtome
- Medical Hand Sink
- Medical Freezer
- Blood Bank Refrigerator
- Medical Pharmacy Refrigerator
- Analysis Balance
- Medical Destroyer
- In-Vitro Diagnostics
- Hemodialysis Equipment
- Hospital Furniture
- Walking Aids
- First-Aid Products
- Medical Endoscope
- Medical Human Model
- Ophthalmic Equipment
- Dental Equipment
- ENT Equipment
- Home Care Equipment
- Veterinary Equipment
- Medical Consumables
- Personal Protective Equipment
Features
1. 8" LCD display
2. Temperature monitoring
3. Temperature servo control
4. Humidity Monitoring
5. Humidity Servo Control
6. Air temperature and body temperature contorl two modes
7. Mattress tilt ±12 °
8. Ergonomic designed handle with perfect height
9. Trend for 2, 4, 8, 12, 24 hours and up to 7 days
10. Front and rear double-walls and air curtain
11. Drawers Large (28.0cm x 24.7cm x 36.0cm)
12. Drawers Small (28.0cm x 11.3cm x 36.0cm) *2
13. Auxiliary Power Output*3
Technical Specifications
Performance
Air flow velocity across mattress < 10 cm/sec
Temperature rise time at 22°C (72°F) ambient < 20min (From 22℃, 50%RH, to 35℃)
Temperature variability < 0.5℃
Temperature overshoot < 0.5℃ maximum
Temperature uniformity with a level mattress < 0.8℃
Operating noise level in hood ≤45dBa
Carbon Dioxide (CO2) Level <0.5%
Hood
Tubing access ports: 10
Access door size: 18cm x 13cm
Mattress to hood height: 48.0mm
Soft bed mattress size: 73.6cm x38.6cm x1.8cm
Temperature control modes: Skin and air temperature control mode
Air mode control temperature range: 20℃-37℃
Air mode control override temperature range: 37℃-39℃
Air mode control accuracy ≤±1.0℃
Skin mode control temperature range: 34℃-37℃
Skin mode control override temperature range: 37℃-38℃
Skin temperature accuracy: ±0.3℃
Dual-skin temperature monitoring: Yes
Servo Humidity
Humidity control range: 30%-95% RH
Humidity control operating time without refilling: 24 hours
Humidity control reservoir capacity: 1500ml
Humidity display accuracy: ±5%RH
Humidity control accuracy: ±5% RH
Servo Oxygen (Optional)
Oxygen control range: 21 % to 65%
Oxygen display accuracy of full scale: ±2%
Oxygen control accuracy (100% calibration): ±3%
Oxygen control accuracy (21% calibration): ±5%
Oxygen display resolution: 1%
Scale (Optional)
Weight range: 300g to 8kg
Weight display resolution: 1g
Weight accuracy: ±10g
Operating Environment: 20℃ to 30℃
Humidity: 10 to 95% RH
Air Velocity: Up to 0.3m/sec
Backup battery (Optional)
Battery: 2600mAh, 14.8V, 38Wh
This battery is to keep screen, motor and alarm operation after power failure for more than 30 mins, heating and humidification functions are not supported