Products

ASP-1500

Syringe Pump

Features

1.      Open system: Accepts all standard syringes of 5ml, 10ml, 20ml/30ml, 50ml/60ml.

2.      Large COLOR LED display

3.      KVO/Bolus function.

4.      Vertical & Horizontal mounting.

5.      Anti-bolus system to reduce significantly after occlusion sudden release.

6.      Three levels of Occlusion Pressure Alarm.

7.      Three work modes: Rate Mode, Time Mode, Dose Mode

8.      Identify the specifications of syringe automatically.

9.      Audible and visual alarm: Syringe Holder Loose, Syringe Plunger Disengagement, Syringe Flange Insertion Error, Syringe Not Calibrated, Occlusion, Syringe Empty, Rate Abnormal, Battery Empty, No Battery, Key Holding During Infusion, Key Holding During Pause, Infusion Complete, Syringe Near Empty, No Action, Battery Low, Out of Flow Range

10.   Stackable: Users can freely stack one syringe pump onto another to provide multiple Solutions

11.   Power lost memory.

12.   Visual and audible alarm system and accurate injection rate make the process safer and reliable.

13.   Change the flow rate without stop during infusion.

14.   8-10 Hours Internal Li-Battery continuous operation.

15.   Accurate and sensitive pressure sensor detects occlusion pressure accurately.

16.   Excellent injection operation. The accuracy will be ensured even at small-volume injection.

Technical Specifications

PARAMETER

SPECIFICATION

Applicable syringes

5ml,10ml,20ml,30ml,50ml,60ml of any standard

Accuracy

+/- 5% with correct calibration

Rate mode

50ml(60ml): 0.1ml/h-2000.0ml/h (0.1ml/h or 1ml/h step)

30ml: 0.1ml/h-1200.0ml/h (0.1ml/h or 1ml/h step)
20ml: 0.1ml/h-800.0ml/h (0.1ml/h or 1ml/h step)
10ml: 0.1ml/h-400.0ml/h (0.1ml/h or 1ml/h step)

5ml: 0.1~200ml/h (0.1ml/h or 1ml/h step)

Time Mode

SOL. VOL: 0.1-9999.9ml (0.1ml step)
TIME: 00:01-99:59min (1min step)

Dose Mode

Volume: 0.1-999.9ml (0.1ml step)
DRUG MASS: 0.1-999.9mg 0.1mg step)
DOSE: 0.001-9999ug/kg/min (0.001ug/kg/min step)
WEIGHT: 0.1-300kg (0.1kg the least step)

Dose unit: ng/kg/min, ug/kg/min, mg/kg/min, g/kg/min, ug/kg/h, mg/kg/h, g/kg/h, ug/min, mg/min, g/min, ug/h, mg/h, g/h, U/min, U/h, IU/h, U/kg/h, ml/h

Total Volume Range

0.1-9999ml (0.1 ml step)

Purge Rate

50ml(60ml): 1500.0ml/h,

30ml: 1200.0ml/h,

20ml: 800.0ml/h

10ml: 400.0ml/h, 5ml: 200ml/h

KVO Rate

3ml/h when the delivery rate ≥3ml/h, otherwise KVO is the actual delivery rate

DPS dynamic pressure

Three levels setting Low (60±15kPa), Medium (90±15kPa), High (120±15kPa)

Alarms

Syringe Holder Loose, Syringe Plunger Disengagement, Syringe Flange Insertion Error, Syringe Not Calibrated, Occlusion, Syringe Empty, Rate Abnormal, Battery Empty, No Battery, Infusion Complete, Syringe Near Empty, No Action, Battery Low

Three levels of alarm volume LOW, MEDIUM or HIGH

Bolus Rate

5ml: 0.1~200ml/h,10ml:0.1-400ml/h,20ml:0.1-800ml/h,

30ml:0.1-1200ml/h,50ml(60ml):0.1-2000ml/h

Programmable and adjustable

Bolus Volume

Range: 1.0~50.0ml, (0.1ml step)

Interface

RS-232

Power source

AC power supply: AC 100 to 240V( +/-10%)50/60Hz;

DC Power supply: 12~15V, power>15W;

Built-in Lithium Battery: Rechargeable, 11.1V, 2000mAh.

8 -10hours of continuous operation

Accessories:

AC power line, Operational manual

Protection Class

Class I, Type CF, IP34

Dimension / N.W

240mm*150mm*117mm, 2.0kg

Packing size/G.W

300mm*260mm*160mm, 3.0KG


Copyright © 2001-2024 ARI Medical Technology Co., Ltd. - ARI Technology Group Co., Ltd. All Rights Reserved.