Products
-
- Operating Theatre Equipment
- OB/GYN Equipment
- Diagnostic Equipment
- Sterilizer (Autoclave)
- X-ray Series
- Laboratory Equipment
- Biological Microscope
- Spectrophotometer
- High Speed Centrifuge
- Low Speed Centrifuge
- High Speed Freeze Centrifuge
- Low Speed Freeze Centrifuge
- Special Centrifuge
- Thermostatic Bath
- Laboratory Shaker
- Laboratory Mixer
- Water Distiller
- Magnetic and Electric Stirrer
- Laboratory Incubator
- Dry Oven
- PH Meter
- Biological Safety Cabinet
- Clean Workbench
- Water Purifier
- Ultrasonic Cleaner
- Pipette
- Microtome
- Medical Hand Sink
- Medical Freezer
- Blood Bank Refrigerator
- Medical Pharmacy Refrigerator
- Analysis Balance
- Medical Destroyer
- In-Vitro Diagnostics
- Hemodialysis Equipment
- Hospital Furniture
- Walking Aids
- First-Aid Products
- Medical Endoscope
- Medical Human Model
- Ophthalmic Equipment
- Dental Equipment
- ENT Equipment
- Home Care Equipment
- Veterinary Equipment
- Medical Consumables
- Personal Protective Equipment
Technical Specifications
PARAMETER |
SPECIFICATION |
Sample/Reagent position |
40pcs sample position |
Reagent refrigerated function |
|
40pcs reagent position |
|
Reacting system |
Reaction cuvette:60 reusable plastic units |
Optical length of cuvette:6mm |
|
Max reaction time:10 minutes |
|
Reaction temperature:37±0.1°C |
|
Reaction cuvettes |
Reaction Cuvette: 60 reusable plastic cuvettes |
Automatic blank testing for cuvette |
|
Colorimetry system in the pattern of light splitting behind cuvette |
|
Dismountable,easily replacement |
|
Optical System |
Light Source: halogen-tungsten lamp |
Wavelength: 340-690nm,9 wavelengths,precision ±1.5nm |
|
Absorbance range:0~5.0 Abs |
|
Resolution:0.0001 Abs |
|
Rear spectrophotometry |
|
Optimum calibration cuvette |
Automatic cuvette blank testing |
Automatic wash selected cuvettes |
|
Calibration |
Calibration: linear/nonlinear multi-points calibration |
Re-test: retest the sample automatically when the result is out of the linearity range or the sample is not sufficient |
|
Sample Reagent/Mixing probe |
Automatic liquid level detect |
Collision protection function |
|
Probe internal/external washing |
|
Independent mixing probe |
|
7-step auto cleaning system |
Automatic 7-step washing |
Hi-tech washing station to ensure accurate results |
|
With low water consumption:1-2L/H |
|
Intellective software |
Automatic washing cuvette when startup&shut down |
Automatic detect reagent volume during every startup |
|
Reagent plate temperature detecting when startup |
|
Dynamic and real-time display of running status |
Real-time online monitoring running status of sample tray, reagent tray and cuvette |
Real-time online monitoring reagents residual volume |
|
Real-time online monitoring waste volume |
|
Automatic dilute and re-test |
Automatic dilute and re-test when absorbance range is out of range |
Automatic dilute and re-test when linear limit is out of range |
|
Automatic dilute and re-test when linear range is out of range |
|
Freely set the auto dilute ratio and dilute water position |
|
Size |
54.8cm×42.2cmX38.3cm |
Net weight |
≤23kg |
Optimal substitution of semi-auto biochemistry analyzer
|
Minimal labor required |
Independent mixing probe |
|
Utility of reagents decreased:300ul/test |
|
Efficiency speed:200 tests/hour |
|
User friendly: Smart and easy-operating software |
|
High Accuracy: Minimal operating/random errors |
|
High reputation from clinics |
|
System functions
|
Analysis Methods: end-point, kinetic, two-point, double-reagent, double-wavelength, multi-standard etc, open to various reagents |
Sample/Reagents Handling |
Sample volume:1.6-50μl,0.1μl step |
Sample Dilution: automatic/Manual pre-dilution, with dilution ratio up to 1:100 |
|
Reagent Position: 40pcs |
|
Reagent Volume:10-500μl,0.5μl step |
|
Working condition |
Power Supply:100-240V,50/60Hz,300VA |
Temperature:10-35℃ |
|
Humidity:≤90% no dew |
|
Operation system |
Windows 10 or Windows 7 |
Input and Output |
Input: RS-232 interface/computer |
Output: multi-format printout |