Products
-
- Operating Theatre Equipment
- Anaesthesia Machine
- Ventilator
- Defibrillator
- Electrosurgical Unit
- Ultrasonic Scalpel
- Patient Monitor
- Medical Pendant
- LED Operating Lamp
- Operating Lamp
- Operating Table
- Delivery Table
- Suction Unit
- Syringe Pump
- Infusion Pump
- Feeding Pump
- Blood Infusion Warmer
- Operating Microscope
- Shockwave Lithotripter
- Surgical Tools
- OB/GYN Equipment
- Diagnostic Equipment
- Sterilizer (Autoclave)
- X-ray Series
- Laboratory Equipment
- Biological Microscope
- Spectrophotometer
- High Speed Centrifuge
- Low Speed Centrifuge
- High Speed Freeze Centrifuge
- Low Speed Freeze Centrifuge
- Special Centrifuge
- Thermostatic Bath
- Laboratory Shaker
- Laboratory Mixer
- Water Distiller
- Magnetic and Electric Stirrer
- Laboratory Incubator
- Dry Oven
- PH Meter
- Biological Safety Cabinet
- Laminar Flow Cabinet
- Water Purifier
- Ultrasonic Cleaner
- Pipette
- Microtome
- Medical Hand Sink
- Medical Freezer
- Blood Bank Refrigerator
- Medical Pharmacy Refrigerator
- Analysis Balance
- Medical Destroyer
- In-Vitro Diagnostics
- Hemodialysis Equipment
- Hospital Furniture
- Walking Aids
- First-Aid Products
- Medical Endoscope
- Medical Human Model
- Ophthalmic Equipment
- Dental Equipment
- ENT Equipment
- Home Care Equipment
- Veterinary Equipment
- Medical Consumables
- Personal Protective Equipment
- Operating Theatre Equipment
Features
This product is intended to provide ventilation assistance and breathing support for adult, pediatric and infant patients.
There are no absolute contraindications for this product. For some special diseases, however, some necessary treatments shall be taken for ventilator mechanical ventilation, or special ventilation modes shall be adopted to prevent possible patient injury.
Technical Specifications
Turbine Based
-Shorter triggering and inspiratory delay
-Powerful non-invasive ventilation
-Compressor Free
-Central Gas Free
-Less cost
Control
-AR-V6 is a fully electronic control ventilator,
-Tidal Volume: 5-2000ml (optional 2-2000ml)
-A wide range of TV adjustments allows the medical team to tailor the ventilator to multiple types/needs of patients, even with NICU patients.
Ventilation Modes
a. Invasive Ventilation Modes:
VC-ACV, PC-ACV, PRVC, VC-SIMV, SIMV-PRVC, PC-Dual PAP, PC-APRV, CPAP/PSV, CPAP/VG, AMV/MMV, nCPAP, Apnea Ventilation
b. Non-Invasive Ventilation Modes:
PC-ACV, PRVC, SIMV-PRVC, PC-Dual PAP, PC-APRV, nCPAP, CPAP/PSV, CPAP/VG, AMV/MMV, Apnea Ventilation
c. HFNC
Tools
-Rlung, RSBI, P0.1, PEEPi, V-CO2, PTP, Expiratory Hold, sigh, ATC, PCVR, PPS, Compliance, calibration, O2 suction, 100% O2, and more adding
-Screen Freeze and Lock
-Lung measurement tools: 3 loops;
Multi-Clinical Demands
Departments: ICU, CCU, PACU, NICU, EICU, OR, In-Hospital Transport, etc.
Suitable for:
-Adult and pediatric intensive care
-Neonatal intensive care
-Critical care transport
-Long-term acute care
Characteristics
-Advanced automated adaptive assisted wide-range ventilation system with electronic
microprocessor controlled by volume and pressure to fit for all types of patients from Neonates,
Pediatrics to Adults.
-Both invasive and non-invasive modes make the unit wide applications.
-Integrated self- check system with leak check and system tightness to secure the ventilation
result (POST: Power On self-test).
-Automatic leakage compensation by the unit provides is giving to optimize respirator settings
-Two Lithium batteries guarantee the unit usage up to 6 hours.
-Manual settable Inspiratory pause from 0.1- 6seconds.
-The unit is with automatic triggers adjustment both on flow trigger and pressure trigger.
-The unit is with measurement of volumetric capnography of CO2 (Optional ETCO2 measurement function)
-AMV mode can minimize the work of breathing under the target minute ventilation. (Optional)
Spo2 interfaces
SPO2 can directly Visual display the concentration of blood oxygen; lt is an important index to judge the function of ventilation and air change.
High and low pressure oxygen interface
The low pressure oxygen interface can be connected to the hyperbaric oxygen cylinder or the central oxygen supply, so that the ventilator can provide sufficient oxygen for patients when ensuring the breathing of mild and severe patients, so as to improve the oxygenation of patients.
The independent low-pressure oxygen interface can be connected to the oxygen pillow or small oxygen bottle to facilitate the hospital transportation and ensure the safety of patients.
Neonatal Function (optional)
The minimum tidal volume is 2ml. It is suitable for newborns and even premature infants to avoid barotrauma;
Meet the needs of patients of different ages, provide individualized treatment, more accurate and safer.
EtCO2 (optional)
EtCO2 showed the concentration of CO2 in blood during ventilation, reflecting the effect of ventilation; It is an important index to judge hyperventilation or hypoventilation.
Double index real-time monitoring at the same time, more convenient, more intuitive, more secure.