AED-5000

AED Defibrillator

Specifications and Features

Specifications

Type: Automatic External Defibrillator AED

Self-test: Daily, Weekly, Monthly

Mode:  Adult, Child

Waveform: Biphasic truncated exponential

Energy: 200 Joule max.

Energy Sequence (programmable): 50,50,75 Joule

                                                         150, 150, 200 Joule

Charge time (at 25): Less than 6 sec. to 150J

Less than 8 sec. to 200J

Voice Prompt: Extensive voice prompt

Visual Indicators: LED prompts

Control (Two buttons): ON/OFF, Shock

ECG storage: 1500 events

Data transmission: Infrared

Waveform gain: 5mm/mv10mm/mv20mm/mv

Waveform speed: 12.5mm/s25mm/s50mm/s

Advantages

2 languages to choose (by end user)

5 levels of sound volume (by end user)

Adult / Child mode Button

Infra-red for data transmission (standard)

Daily, Weekly and Monthly self-test

Using the AED while in bag (don’t need to open the bag while using the machine)

Extra pocket of carry bag for storing first aid products

IPX55 water and dust resistant

Features

Three-step defibrillation process defibrillator

Selectable Energy for different age patients: 50, 50, 75 Joule; 150, 150, 200 Joule

Extensive voice and visual prompts for the operator

Changeable language manually

Biphasic energy output

Lock-out protection to prevent inadvertent defibrillation

Device has an internal memory (60 hours)

ECG signals and events can be transferred to the computer

Provided with carrying case, battery, pads, software for data transmission

Long-life disposable LiMnO2 type battery (battery life of at least 5 years)

AED Storage Software (standard configuration)

It’s used to assist the supervisory system of Automatic External Defibrillator

The interface display status information recorded in the running of the AED, including type, event time, description, waves.

Event type includes on event, self-test event, analyzing event, charging event, discharging event, CPR starting event, CPR stopping event. The event time displays when the event happens.

Description shows the parameter information. “OHM” represents the detected impedance of the patient. Power parameter represents the voltage of the finished charging. “Need to shock” represents that shock advised after analyzing. “No need to shock” represents that no shock advised after analyzing. Waveform represents the link of the ECG waves.

Print ECG

Click the “print” in ECG waveform display interface, then enter the setting interface of print.

Battery

Power: 12V, 3000mAh

Type: Non-rechargeable Li-MnO2 Cell

Environmental Operating Temperature: 0 to 40

Operating Humidity: Relative humidity between 30% and 95% (non-condensing)

Storage Temperature (without battery): -20 to 55

Storage Humidity (without battery): Up to 93% (non-condensing)

Weight (with battery): 1.9Kg (4.2 pounds)

Configuration

Standard

AED Pad              1Pcs

Battery                 1Pcs

AED Case            1Pcs

Cleaning Cloth     1Pcs

CD Software for ECG Data transfer

Optional

AED Cabinet

USB Adapter for ECG Data transfer

 