Products
-
- Operating Theatre Equipment
- OB/GYN Equipment
- Diagnostic Equipment
- Sterilizer (Autoclave)
- X-ray Series
- Laboratory Equipment
- Biological Microscope
- Spectrophotometer
- High Speed Centrifuge
- Low Speed Centrifuge
- High Speed Freeze Centrifuge
- Low Speed Freeze Centrifuge
- Special Centrifuge
- Thermostatic Bath
- Laboratory Shaker
- Laboratory Mixer
- Water Distiller
- Magnetic and Electric Stirrer
- Laboratory Incubator
- Dry Oven
- PH Meter
- Biological Safety Cabinet
- Clean Workbench
- Water Purifier
- Ultrasonic Cleaner
- Pipette
- Microtome
- Medical Hand Sink
- Medical Freezer
- Blood Bank Refrigerator
- Medical Pharmacy Refrigerator
- Analysis Balance
- Medical Destroyer
- In-Vitro Diagnostics
- Hemodialysis Equipment
- Hospital Furniture
- Walking Aids
- First-Aid Products
- Medical Endoscope
- Medical Human Model
- Ophthalmic Equipment
- Dental Equipment
- ENT Equipment
- Home Care Equipment
- Veterinary Equipment
- Medical Consumables
- Personal Protective Equipment
Product Introduction
The unit disinfects and sterilizes the objects with saturated
steam, by the means of pulsely exhausting the cold air to clear the efforts
from which to the temperature, and make the objects completely drying by the
way of vacuum-exhausting and jacket baking. By using the physical
characteristics of the pressured saturated steam will releasing plenty of hot
while condensing, the unit will keep the sterilizing objects wet and at high
temperature in a given time, which spoils the virus and the spores together,
and good sterilizing efforts will be received.
Technical Specifications
Chamber Volume: |
50 Liters |
Max working temperature: |
134℃±1℃ |
Max working pressure: |
0.22mpa |
Adjusted sterilizing temperature range: |
55℃~134℃ |
Adjusted timer range: |
1~99mins |
Adjusted drying time range: |
1~99mins |
Vacuum limit: |
-0.08mpa |
Hot Average: |
≤2℃ |
Power supply: |
AC220V/50HZ |
Dimension: |
770×600×540 mm |
Transport dimension: |
880×730×700 mm |
Gross/Net Weight |
130/106 kg |
Features
1. The sterilizing procedure is automatically controlled, it is not necessary to be supervised, and used conveniently.
2. At lease 3 or more times pulse-vacuum exhausting, which is applied to wrapped or unwrapped objects,hollow equipment.
3. Drying function.
4. With inner printer, which record the for the full procedure of the sterilization.
5. With Bowie&Dick testing function, which is for the steam penetrating testing.
6. Self-testing malfunction, easy to maintain.
7. Safety functions:
Safety locking: the steam can not enter the chamber and the unit will alarm when the door is not closed tightly,and the door can not the open when the inner pressure is exceed 0.027mpa.
Over pressure protection:
-If the pressure exceed the working pressure, the safety valve will exhausting the air.
Low water protection:
-The unit can not be started if the water don’t reach the high level,and the power will cut off directly.
-Over current protection:
The broker will cut off the power by the over current happened.