Products

AR-321

Anesthesia Machine


Technical Specifications

PARAMETER

SPECIFICATION

Main Body

High-strength engineering plastic rack, light, beautiful and corrosion resistant

Scope of Application

Adult, child

Gas Source

O2: 0.28--0.6MP

Flow Meter

O2: 0.05--1.0L/min; 1.1--10L/min

Flow Rate of Rapid Supply

25--75L/min

Low Oxygen Pressure Alarm

It will be sound alarm when the oxygen pressure < 0.2MPa

Vaporizer

It has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0-5vol%.

Among Halothane, Enflurane, Isoflurane and Sevoflurane, one can be chosen for application as required by the customer.

Respiratory Circuit

Working mode: all-close, semi-close, semi-open

APL: 12.5kPa.

Respiratory Bellows

Bellows for adults, bellows for children, tidal volume range:0-1500ml

VENTILATOR

Display Mode

High-definition 5.7” LCD screen display

Ventilation Mode

IPPV, SIPPV, SIMV, MANUAL

Ventilation Function

PEEP, SIGH, IRV

Ventilation Parameters

Tidal volume           50~1500ml

Rate                  2~99bpm

SIMV rate                   2~20bpm

I:E                  2:1~1:8

SIGH          1.5 times the inspiratory time/100bpm

Inspiratory trigger pressure   -10~20cmH2O

PEEP                 2~20cmH2O

Pressure limitation      10~60cmH2O

Parameters for Ventilation

Monitoring

Tidal volume, Minute ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway-pressure-time waveform, flow rate-time waveform, PEEP, inspiratory trigger pressure, (average pressure, oxygen concentration, battery capacity).

SECURITY ALARM SYSTEM

Oxygen Concentration Alarm

Upper limit setting range   (21%~99%)

Low limit setting range     (18%~80%)

Airway Pressure Alarm

Upper limit setting range   55~60cmH2O

Low limit setting range     0~50cmH2O

Minute Ventilation Volume Alarm

Upper limit setting range   1~20L/min

Low limit setting range     0~19L/min

Tidal volume

Upper limit setting range   100~1500ml

Low limit setting range     0~1400ml

Sustained High-pressure

Alarm

It will give alarm when stress have consistently been higher than

25cmH2O

(Suffocation Alarm, Power alarm, Intubation off alarm, battery voltage alarm)

Power

AC 220V, 50Hz, (UPS, Storage battery)

(Mechanical Arms)

(End-tidal CO2 Monitoring)

(Specific interface of waste anesthesia gas)

*Note: Items within brackets are optional