Products
-
- Operating Theatre Equipment
- OB/GYN Equipment
- Diagnostic Equipment
- Sterilizer (Autoclave)
- X-ray Series
- Laboratory Equipment
- Biological Microscope
- Spectrophotometer
- High Speed Centrifuge
- Low Speed Centrifuge
- High Speed Freeze Centrifuge
- Low Speed Freeze Centrifuge
- Special Centrifuge
- Thermostatic Bath
- Laboratory Shaker
- Laboratory Mixer
- Water Distiller
- Magnetic and Electric Stirrer
- Laboratory Incubator
- Dry Oven
- PH Meter
- Biological Safety Cabinet
- Clean Workbench
- Water Purifier
- Ultrasonic Cleaner
- Pipette
- Microtome
- Medical Hand Sink
- Medical Freezer
- Blood Bank Refrigerator
- Medical Pharmacy Refrigerator
- Analysis Balance
- Medical Destroyer
- In-Vitro Diagnostics
- Hemodialysis Equipment
- Hospital Furniture
- Walking Aids
- First-Aid Products
- Medical Endoscope
- Medical Human Model
- Ophthalmic Equipment
- Dental Equipment
- ENT Equipment
- Home Care Equipment
- Veterinary Equipment
- Medical Consumables
- Personal Protective Equipment
Technical Specifications
PARAMETER |
SPECIFICATION |
Main Body |
High-strength engineering plastic rack, light, beautiful and corrosion resistant |
Scope of Application |
Adult, child |
Gas Source |
O2: 0.28--0.6Mpa; N2O: 0.28--0.6MPa. |
Flow Meter |
O2: 0.05--10L/min; N2O: 0.05--10L/min |
O2, N2O Linkage and N2O Stopper |
When using nitrous oxide, oxygen concentration>25%; When the oxygen pressure < 0.2MPa, the flow of nitrous oxide would be cut off. |
Flow Rate of Rapid Oxygen Supply |
25--75L/min |
Low Oxygen Pressure Alarm |
There will be sound alarm when the oxygen pressure < 0.2MPa |
Vaporizer |
It has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0-5vol%. Among Halothane, Enflurane, Isoflurane and Sevoflurane, one can be chosen for application as required by the customer. And vaporizers that are imported with original packaging are also available. |
Respiratory Circuit |
Working mode: all-close, semi-close, semi-open; APL: ≤12.5kPa. |
Respiratory Bellows |
Bellows for adults, bellows for children, tidal volume range 0-1500ml |
VENTILATOR |
|
Display Mode |
High-definition 5.7” LCD screen display |
Ventilation Mode |
IPPV, SIPPV, SIMV, MANUAL |
Ventilation Function |
PEEP, SIGH, IRV |
Ventilation Parameters |
Tidal volume 50~1500ml Rate 2~99bpm SIMV rate 2~20bpm I:E 2:1~1:8 SIGH 1.5 times the inspiratory time/100bpm Inspiratory trigger pressure -10~20cmH2O PEEP 2~60cmH2O Pressure limitation 10~60cmH2O |
Parameters for Ventilation Monitoring |
Tidal volume, Minute ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, pressure-time waveform, flow rate–time waveform, PEEP, inspiratory trigger pressure, (average pressure, oxygen concentration, battery capacity). |
SECURITY ALARM SYSTEM |
|
Oxygen Concentration alarm |
Upper limit setting range (21%--99%) Low limit setting range (18%--80%) |
Airway pressure alarm |
Upper limit setting range 5--60cmH2O; Low limit setting range 0--50cmH2O. |
Minute ventilation volume alarm |
Upper limit setting range 1--20L/min; Low limit setting range 0--19L/min. |
Tidal Volume |
Upper limit setting range 100--1500ml Low limit setting range 0--1400ml |
Sustained high-pressure alarm |
It will give alarm when stress have consistently been higher than 25 cmH2O |
Suffocation alarm |
It will give sound and light alarm if there is no tidal volume input for 15 seconds |
(Suffocation Alarm, Power alarm, Intubation off alarm, battery voltage alarm) |
|
Power |
AC 220V, 50Hz, (Storage battery, UPS) |
Mechanical Arms |
|
(End-expiratory CO2 monitoring) |
|
(Specific interface of waste anesthesia gas) |
|
*Note: Items within brackets are optional. |