Products
-
- Operating Theatre Equipment
- OB/GYN Equipment
- Diagnostic Equipment
- Sterilizer (Autoclave)
- X-ray Series
- Laboratory Equipment
- Biological Microscope
- Spectrophotometer
- High Speed Centrifuge
- Low Speed Centrifuge
- High Speed Freeze Centrifuge
- Low Speed Freeze Centrifuge
- Special Centrifuge
- Thermostatic Bath
- Laboratory Shaker
- Laboratory Mixer
- Water Distiller
- Magnetic and Electric Stirrer
- Laboratory Incubator
- Dry Oven
- PH Meter
- Biological Safety Cabinet
- Clean Workbench
- Water Purifier
- Ultrasonic Cleaner
- Pipette
- Microtome
- Medical Hand Sink
- Medical Freezer
- Blood Bank Refrigerator
- Medical Pharmacy Refrigerator
- Analysis Balance
- Medical Destroyer
- In-Vitro Diagnostics
- Hemodialysis Equipment
- Hospital Furniture
- Walking Aids
- First-Aid Products
- Medical Endoscope
- Medical Human Model
- Ophthalmic Equipment
- Dental Equipment
- ENT Equipment
- Home Care Equipment
- Veterinary Equipment
- Medical Consumables
- Personal Protective Equipment
Features
1. Air mode and baby mode controlled by micro-computer
2. Use AC Power and DC Power alternatively, DC 12V or DC 24V Power on the ambulance
3. Set temperature, air temperature, skin temperature and internal battery power are displayed by LED
4. Self-testing function, various failure alarms by audible and visual
5. Alarm function:
6. Power failure, Over temperature, Temperature deviation, Fan failure, Temperature sensor failure
7. Double wall hood with side door and front door,4 operating windows and 1 iris ports,6 infusion seals
8. The infant bed can be pulled out from side door easily
9. Natural air flow humidity
10. The height of whole unit is adjustable
11. Oxygen supply system
12. LED observe light, adjustable brightness
13. Build-in storage cabinet
Technical Specifications
Performance |
||
Power supply |
AC110/220V, 60/50Hz |
|
Power input |
450VA |
|
Air temperature control range |
25°C~37°C 37.1°C~38°C |
|
Skin temperature control range |
32°C~37°C 37.1°C~37.5°C |
|
Air/Skin temperature sensor accuracy |
±0.3°C |
|
Temperature fluctuation |
±1°C |
|
Uniformity of mattress temperature |
≤1.5°C |
|
Air temperature deviation alarm |
±3°C |
|
Skin temperature deviation alarm |
±1°C |
|
Warm-up time |
≤40min |
|
Internal noise level |
≤60dB(A) |
|
Main battery |
DC12V 40AH, Li-ion battery |
|
Infant bed tilt angle |
±12° |
|
Charge time |
12 hours |
|
Battery use time |
2 hours |
|
Auxiliary battery |
DC8.4V 0.17AH,Li-ion battery |
|
Mattress size |
65cm(L)*32cm(W) |
|
Trough capacity |
1200mL |
|
Air filter |
0.5μm |
|
Operating Condition |
||
Environment temperature |
10°C~30°C |
|
Environment relative humidity |
30%~75% |
|
Environment air velocity of flow |
<1m/s |
|
Transport and Storage |
||
Environment temperature |
-40°C~+55°C |
|
Environment relative humidity |
≤95% |
|
Atmospheric Pressure |
500~1060hpa |
|
Package |
||
Each unit is packed in two cartons |
||
Carton 1 Dimension |
103*73*87cm (hood) |
N.W. 65KGS, G.W:85KGS |
Carton 2 Dimension |
1147*69*56cm (small trolley) |
N.W. 40KGS, G.W:50KGS |
Standard Configuration |
||
Main body (Including the transparent hood, double hood,control system,infant bed,water trough,skin temperature sensor, two oxygen cylinders |
||
I.V Pole |
||
Mattress |
||
Observe light |
||
Optional Functions |
||
Infant resuscitator |
||
Low pressure aspirator |
||
Ambulance trolley |