Products
-
- Operating Theatre Equipment
- OB/GYN Equipment
- Diagnostic Equipment
- Sterilizer (Autoclave)
- X-ray Series
- Laboratory Equipment
- Biological Microscope
- Spectrophotometer
- High Speed Centrifuge
- Low Speed Centrifuge
- High Speed Freeze Centrifuge
- Low Speed Freeze Centrifuge
- Special Centrifuge
- Thermostatic Bath
- Laboratory Shaker
- Laboratory Mixer
- Water Distiller
- Magnetic and Electric Stirrer
- Laboratory Incubator
- Dry Oven
- PH Meter
- Biological Safety Cabinet
- Clean Workbench
- Water Purifier
- Ultrasonic Cleaner
- Pipette
- Microtome
- Medical Hand Sink
- Medical Freezer
- Blood Bank Refrigerator
- Medical Pharmacy Refrigerator
- Analysis Balance
- Medical Destroyer
- In-Vitro Diagnostics
- Hemodialysis Equipment
- Hospital Furniture
- Walking Aids
- First-Aid Products
- Medical Endoscope
- Medical Human Model
- Ophthalmic Equipment
- Dental Equipment
- ENT Equipment
- Home Care Equipment
- Veterinary Equipment
- Medical Consumables
- Personal Protective Equipment
Features
1. Microprocessor based servo-controlled temperature system
2. The microprocessor-controlled unit allows for three modes: pre-warm, manual and automatic
3. APGAR timer to record therapy time
4. Audible and visual alarm functions:
Power failure, temperature deviation, temperature sensor failure, skin temperature failure, over temperature
5. Heater head can be adjusted ±90°horizontally
6. Convenient X-ray cassette tray under infant mattress
7. Tilt angle of infant bed is adjustable
8. LED observation light adjustable,brightness adjustable
9. A second thermal cut-out function for more safety
10. Four Transparent protector folded with 2 infusion seals
11. Skin temperature sensor failure protect function avoid over temperature
12. RS-232 connector, 1 tray
Technical Specifications
Performance |
|
Power supply |
AC110/220V, 60/50Hz |
Power input |
900VA |
Skin Temperature control range |
32°C~38°C |
Skin temperature control accuracy |
≤0.5°C |
Skin temperature sensor accuracy |
±0.3°C |
Mattress temperature uniformity |
<2°C |
Infant bed tilt angle |
±10° |
Warm-up time(from 25°C) |
<30min |
Heater head horizontal |
±90°C |
Distance from heater to mattress |
80cm |
Mattress size |
67cm*54cm |
Timer range |
0~99h59min |
Operational Condition |
|
Environment temperature |
18°C~30°C |
Environment relative humidity |
30%~75% |
Atmospheric pressure |
700~1060hpa |
Environment air velocity of flow |
<0.3m/s |
Transport and storage |
|
Environment temperature |
-40°C~+55°C |
Environment relative humidity |
≤95% |
Atmospheric Pressure |
500~1060hpa |
Package |
|
Each unit is packed one Carton |
|
Carton size |
110*81*83cm |
N.W/G.W |
40KG/60KG |
Standard configuration |
|
1) Main Body (including the radiant source,control system,infant bed, bracket) |
|
2) I.V Pole |
|
3) Skin temperature sensor |
|
4) Tray |
|
5) Mattress |
|
6) Transparent protector |
|
7) Castors |
|
8) RS-232 |