Products
-
- Operating Theatre Equipment
- OB/GYN Equipment
- Diagnostic Equipment
- Sterilizer (Autoclave)
- X-ray Series
- Laboratory Equipment
- Biological Microscope
- Spectrophotometer
- High Speed Centrifuge
- Low Speed Centrifuge
- High Speed Freeze Centrifuge
- Low Speed Freeze Centrifuge
- Special Centrifuge
- Thermostatic Bath
- Laboratory Shaker
- Laboratory Mixer
- Water Distiller
- Magnetic and Electric Stirrer
- Laboratory Incubator
- Dry Oven
- PH Meter
- Biological Safety Cabinet
- Clean Workbench
- Water Purifier
- Ultrasonic Cleaner
- Pipette
- Microtome
- Medical Hand Sink
- Medical Freezer
- Blood Bank Refrigerator
- Medical Pharmacy Refrigerator
- Analysis Balance
- Medical Destroyer
- In-Vitro Diagnostics
- Hemodialysis Equipment
- Hospital Furniture
- Walking Aids
- First-Aid Products
- Medical Endoscope
- Medical Human Model
- Ophthalmic Equipment
- Dental Equipment
- ENT Equipment
- Home Care Equipment
- Veterinary Equipment
- Medical Consumables
- Personal Protective Equipment
Features & Applications
The cabinet utilize the physical characteristics of the saturated steam, which would release large amounts of latent heat and humidity during condensation, and with a period of time to keep the objects at high temperature and moist condition, the main protein of the bacteria would be solidified so that the bacteria can be killed.
Characteristics
The main body is with horizontal rectangle double layer structure, the inside chamber is made of SUS30408 or SUS31608 Stainless steel, the outer layer is made of the brushed decorative sheet, and the there is motorized door or sliding door for choose, pneumatic sealing, and the double door interlocking are strictly in accordance with the GSSD required.
The control system: Adopt the Siemens PLC and Siemens touch screen.
The piping system:
Adopt with the reliable Germany Burkert or GEMU pneumatic angle type value, water ring vacuum pump and 0.22um high efficiency sterile medical grade filters, the pipe clamp adopts the quick connectors, the piping and the related spares are all according to the sanitation standard.
The characteristics for the software
With Germany Siemens PLC platform independent research and development, human-Machin Interaction, convenient for operation.
Software design and manufacture products in strict accordance with the technical requirements for the sterilization process.
The Operating authority is divided into three levels to the manager, the technologist, and the operators.
Program interlocked, by the program is running, the sealing door cannot be open.
All the alarm and the technical figures can be recorded and print.
If the inner chamber is higher than the safety pressured, the door cannot be open.
Perfect products safety protection measure, 4 level emergency treatment of abnormal state.
Sterilizing Cycles
The sterilization cycle to the solid objects:
Applied to the instruments, dressing, utensils and other items
Main Parameter
Items |
WS-0.25 |
WS-0.36 |
WS-0.6 |
WS-0.8 |
WS-1.2 |
WS-1.5 |
WS-2.0 |
WS-2.5 |
Capacity |
0.25m3 |
0.36m3 |
0.6m3 |
0.8m3 |
1.2m3 |
1.5m3 |
2.0m3 |
2.5m3 |
Inner chamber Dimension (mm) |
800*600*600 |
1000*600*600 |
1200*610*910 |
1500*610*910 |
1500*680*1180 |
1900*680*1180 |
1700*1000*1200 |
1950*1000*1400 |
Outer Dimension (mm) |
1100*1300*1700 |
1300*1300*1700 |
1500*1350*1950 |
1800*1350*1950 |
1790*1450*1950 |
2190*1450*1950 |
2000*1850*2000 |
2300*1850*2200 |
Steam pressure and the consumption |
0.4-0.8 Mpa 15kg |
0.4-0.8 Mpa 20kg |
0.4-0.8 Mpa 30kg |
0.4-0.8 Mpa 40kg |
0.4-0.8 Mpa 48kg |
0.4-0.8 Mpa 60kg |
0.4-0.8 Mpa 65kg |
0.4-0.8 Mpa 75kg |
Water source pressure and the consumption |
0.15-0.3Mpa 35kg |
0.15-0.3 Mpa 40kg |
0.15-0.3 Mpa 45kg |
0.15-0.3 Mpa 50kg |
0.15-0.3 Mpa 55kg |
0.15-0.3 Mpa 60kg |
0.15-0.3Mpa 65kg |
0.15-0.3Mpa 75kg |
Power |
2+24KW |
2+24KW |
3+36KW |
3KW |
4KW |
4KW |
4.5KW |
6KW |
New weight |
900kg |
1000kg |
1400kg |
1600kg |
1800kg |
2000kg |
2500kg |
3000kg |
Design pressure |
0.25Mpa |
|||||||
Design temperature |
139 ℃ |