Products
-
- Operating Theatre Equipment
- OB/GYN Equipment
- Diagnostic Equipment
- Sterilizer (Autoclave)
- X-ray Series
- Laboratory Equipment
- Biological Microscope
- Spectrophotometer
- High Speed Centrifuge
- Low Speed Centrifuge
- High Speed Freeze Centrifuge
- Low Speed Freeze Centrifuge
- Special Centrifuge
- Thermostatic Bath
- Laboratory Shaker
- Laboratory Mixer
- Water Distiller
- Magnetic and Electric Stirrer
- Laboratory Incubator
- Dry Oven
- PH Meter
- Biological Safety Cabinet
- Clean Workbench
- Water Purifier
- Ultrasonic Cleaner
- Pipette
- Microtome
- Medical Hand Sink
- Medical Freezer
- Blood Bank Refrigerator
- Medical Pharmacy Refrigerator
- Analysis Balance
- Medical Destroyer
- In-Vitro Diagnostics
- Hemodialysis Equipment
- Hospital Furniture
- Walking Aids
- First-Aid Products
- Medical Endoscope
- Medical Human Model
- Ophthalmic Equipment
- Dental Equipment
- ENT Equipment
- Home Care Equipment
- Veterinary Equipment
- Medical Consumables
- Personal Protective Equipment
Technical Specifications
PARAMETER |
SPECIFICATION |
|
Display Mode |
10.4-inch High-definition TFT color LCD screen display |
|
Ventilation Mode |
VCV, PCV, SIMV, PSV, PSV+SIMV, CPAP |
|
Ventilation Function |
PEEP, SIGH, standby, IP, IRV |
|
Ventilation Parameters |
Tidal Volume |
20~1800 ml |
Rate |
1~120 bpm |
|
SIMV Rate |
2~20bpm |
|
I:E |
4:1~1:8 |
|
Inspiratory Trigger Pressure |
-10~20 cmH2O |
|
Flow Trigger Sensitivity |
1-20L/min |
|
PEEP |
0~25 cmH2O |
|
Pressure Control |
3~60 cmH2O |
|
Pressure Limit |
5~60 cmH2O |
|
Pressure Slope |
1~10 gear |
|
Flow Rate Setting |
1~10 gear |
|
Expiratory Trigger Sensitivity |
10%~90% |
|
Time Control |
1~10s |
|
SIGH |
1.5 times the inspiratory time(60-120 times adjustable) |
|
Inspiratory Platform |
0~50% |
|
Oxygen Concentration |
21%~99% |
|
Parameters for Ventilation Monitoring |
VI tidal volume, VE tidal volume, Minute Ventilation volume, IPPV rate, SIMV rate, total respiratory rate, autonomous breathing rate, I/E, peak pressure of airway, average pressure, PEEP, Inspiratory trigger pressure, inspiratory platform, oxygen concentration, battery capacity, pressure - time waveform, flow rate - time waveform, flow-volume loop, pressure –volume loop |
|
SECURITY ALARM SYSTEM |
||
Oxygen Concentration Alarm |
Upper Limit Setting Range |
21%~99% |
Low Limit Setting Range |
15%~80% |
|
Airway Pressure Alarm |
Upper Limit Setting Range |
1~60 cmH2O |
Low Limit Setting Range |
0~50 cmH2O |
|
Minute Ventilation Volume Alarm |
Upper Limit Setting Range |
1~30L/min |
Low Limit Setting Range |
0~20L/min |
|
Tidal Volume |
Upper Limit Setting Range |
10~2000ml |
Low Limit Setting Range |
0~1800ml |
|
Respiratory Rate |
Upper Limit Setting Range |
10~99bPm |
Low Limit Setting Range |
0~50bPm |
|
Sustained High-pressure Alarm |
It will give alarm when stress have consistently been higher than 30 cmH2O. |
|
Suffocation Alarm; Gas Shortage Alarm; Low Pressure of Oxygen Alarm; Low Pressure of Air Alarm; Power Alarm; Intubation off Alarm; Battery Voltage Alarm |
||
Power |
AC 220V±10%, 50Hz±1Hz UPS, Storage Battery |
|
Manipulator |
||
Air compressor with “standby” function |