Products

AME 6600

EMG System

Features

1.     Professional EMG/EP operation platform and perfect test projects, complete each test in the shortest time.

2.     Perfect case report data and graph creating system.

3.     Special database management system.

4.     Select test part with Neuro and muscle navigation system and projects selecting system fleetly and conveniently.

5.     Powerful normal value system, contrast with normal data automatically.

6.     Flexible software design, configure systems according to requirements.

7.     High-speed data collection, electromagnetic interference suppression capability for using high strength and light quality metal enclosure.

8.     Simple and convenient operation panel.

9.     Good Electrostatic and electromagnetic interference suppression capability for using high strength and light quality metal enclosure.

10.  Selectable 1-4 channel input mode meets multi-working modes in clinical EMG test.

11.  High-speed collect and process data with parallel processing technology, display data with graph.

Functions

General electromyogram (EMG),Sensory nerve conductor velocity (SCS),motor nerve conductor velocity (MCS), Fwave, HRe-flex, Blink Reflex, Repetitive nerve stimulation (RNS), Brainstem auditory evoked potential (BAEP),Visual evoked potential (VEP),Somatosensory evoked potentials(SEP)

Technical Specifications

PARAMETER

SPECIFICATION

Computer part

CPU

Intel Pentium III (more than 800MHz)

EMS memory

More than 256M

HD

More than 40G

CD driver

CD-ROM or higher configuration

I/O interface

More than USB2.0 interfaces

Operating system

Windows 7,vista,XP 62bit,32bit

Laser printer

Yes

Main system part

A/D conversion resolution

16Bit

Sampling ratio

200kHz

Analysis time

5-5000ms

Amplifier part

Channel

4

Sensitivity

0.05µV-20mV/Grid

CMRR

≥100dB

Filter frequency

Low-pass:1Hz~3000Hz (-3dB)

High-pass:10Hz~20000Hz(-3dB)

Gain amplifies

25 times~400000 times

Stimulator part

Constant current

0.2-100mA

Pulse width

50-1000µS

Stimulation Frequency

1Hz~5Hz

Stimulation type

Single or continuous stimulation

Protection

Short circuit and overloading protection

Auditory stimulator

Stimulation waveform

40Hz short, Sound stim

Stimulation polarity

Non-dense wave, dense wave and alternant wave

Sound intensity

40-120dB (5dB per level)

Frequency of 40Hz carrier wave

500-8000Hz

Visual stimulator

Adopts CRT display whole size

Not less than 200mmx200mm

Mode

Tessellation, horizontal bar and vertical bar

Stimulation view

All-view, half-view and quarter-view

Resolution

3x4,6x8,12x16 ,24x32,48x64

Flash stimulator

All quench, left light, right light, L&R light

Copyright © 2001-2024 ARI Medical Technology Co., Ltd. - ARI Technology Group Co., Ltd. All Rights Reserved.