Products
-
- Operating Theatre Equipment
- OB/GYN Equipment
- Diagnostic Equipment
- Sterilizer (Autoclave)
- X-ray Series
- Laboratory Equipment
- Biological Microscope
- Spectrophotometer
- High Speed Centrifuge
- Low Speed Centrifuge
- High Speed Freeze Centrifuge
- Low Speed Freeze Centrifuge
- Special Centrifuge
- Thermostatic Bath
- Laboratory Shaker
- Laboratory Mixer
- Water Distiller
- Magnetic and Electric Stirrer
- Laboratory Incubator
- Dry Oven
- PH Meter
- Biological Safety Cabinet
- Clean Workbench
- Water Purifier
- Ultrasonic Cleaner
- Pipette
- Microtome
- Medical Hand Sink
- Medical Freezer
- Blood Bank Refrigerator
- Medical Pharmacy Refrigerator
- Analysis Balance
- Medical Destroyer
- In-Vitro Diagnostics
- Hemodialysis Equipment
- Hospital Furniture
- Walking Aids
- First-Aid Products
- Medical Endoscope
- Medical Human Model
- Ophthalmic Equipment
- Dental Equipment
- ENT Equipment
- Home Care Equipment
- Veterinary Equipment
- Medical Consumables
- Personal Protective Equipment
Introduction
AML1205L, AML12L, AML09L use of multiple different sources, by focusing knob, so the beam is irradiated from different locations surgery, reduce the shadow medical staff head, hands and other parts caused. The illumination can be adjusted according to actual needs.
Features
- The no welding titanium alloy main arm is adopted, so that the appearance is aesthetic and the rotation is more flexible and convenient.
- The removable handle sheath can be disinfected at the high temperature of 135℃.
- The depolished panel made of imported material makes the light rays softer.
- The imported switch power supply is adopted to control the voltage, making the work voltage permanently stable.
- The special radiation filter reducing the heat to the minimum level.
- The multi-flake retroreflector made of imported aluminum sheet has the features of no
coating film and never fading.
- Imported lamp receptacle, Tungsten halogen bulbs of international brand are adopted with the average service more than 1500 hours.
- Light adjustment circuit adopts CPU control, enabling increase or decrease of illumination and boasting brightness memory.
- One lamp holder with two bulbs enables automatic operation of the standby bulb in 1/2 second when the main bulb malfunctions, and it has indicators for the damage of main or standby bulb.
Technical Specifications
PARAMETER |
SPECIFICATION |
Major Bulb Illumination |
≥160,000LX |
Color Temperature |
4000K±500K |
Color Rendering Index |
100≥Ra≥85 |
Depth of Light Beam |
≥500mm |
The Value of the Total Irradiance (service range for temperature rise≤10℃) |
≤6mW/m²lx |
Total Irradiance (temperature rise on the head of patient under surgical operation≤2℃) |
≤600W/m² |
Mains Voltage |
AC220V±10%, 50Hz |
Bulb Voltage |
AC24V Bulb Power |
Bulb Power |
425W |
Input Power |
500VA |
Height for Installation |
280-320cm |
Note: If you want use halogen bulbs, please mention before your order. |