Products

Q2000

Real-Time PCR System

Features

1.     Top brand Peltier elements from MARLOW(U.S.A)adopted, ensure long life of 1,000,000 cycles and fast ramping rate up to 6/s.

2.     T-Optical technology, reduce background noise, improve fluorescence signal sensitivity and signal to noise ratio.

3.     The angle of display could be adjusted to the best view.

4.     96 wells* 6 channels, simultaneous detection of wells, not in sequence.

5.     User could view PCR process and run PCR protocol through self-contained 10’’ TFT LCD and touch screen.

6.     Special designed optical system for PCR, avoiding more moving parts problems like  overheat, wear and off center. Not optical fiber based, avoiding break and block.

7.     Long life LED lamps to excite fluorescence and detect with SSLP CCD imaging technology.

8.     Sample wells with temperature gradient function, convenient to optimize PCR conditions.

9.     The drawer design of sample block, makes it easier to pick and place PCR tubes & plates.

10.  The PCR analysis software could be upgrade for free.

Technical Specifications

Instrument Performance

Sample Block Capacity

96 wells * 0.1ml

Reaction Volume

10-50ul(recommend 20ul)

Tubes Option

Low profile, white or clear PCR tubes or strips or 96 well PCR plate, with optical flat cap

Heating and Cooling Technology

New powerful Peltier Technology

Control Methods

Operated via PC or self-contained touch screen on instrument

Temperature

Block Temperature Range

0℃~105

Max. Heating Rate        

6/s

Max. Cooling Rate        

5/s

Temperature Uniformity

≤±0.2(at 90)

Temperature Accuracy

≤±0.1(10 seconds after reach 90)

Display Resolution

0.1

Heat Lid Temperature Range

30~112

Temperature control Mode

Block & Calculated sample

Gradient Range

30~100

Temp. Differential Range

1~30

Fluorescence Detection

Calibrated Dyes at Factory

Excitation

Long life LED lamps

Detection

CCDs

Channel 1

FAMSYBR GREEN

Channel 2

VICHEXJOECY3NED

Channel 3

ROXTEXAS-RED

Channel 4

CY5

Channel 5

CY5.5

Channel 6

Reserved

Fluorescence Excitation Range

300 — 800nm

Fluorescence Detection Range

500 — 800nm

Data Export Formats

Excel, TXT

Dynamic Range

1~1010

Sensitivity

≥1 copy

Fluorescence Detection

AC power supply

100V ~ 240V, 50-60Hz

Consumption

600W

Dimension (L×W×H)

334×280×365mm

Net Weight

13KG

Computer Operating Systems

Windows10Windows7Windows XP

Copyright © 2001-2024 ARI Medical Technology Co., Ltd. - ARI Technology Group Co., Ltd. All Rights Reserved.