Products
-
- Operating Theatre Equipment
- OB/GYN Equipment
- Diagnostic Equipment
- Sterilizer (Autoclave)
- X-ray Series
- Laboratory Equipment
- Biological Microscope
- Spectrophotometer
- High Speed Centrifuge
- Low Speed Centrifuge
- High Speed Freeze Centrifuge
- Low Speed Freeze Centrifuge
- Special Centrifuge
- Thermostatic Bath
- Laboratory Shaker
- Laboratory Mixer
- Water Distiller
- Magnetic and Electric Stirrer
- Laboratory Incubator
- Dry Oven
- PH Meter
- Biological Safety Cabinet
- Clean Workbench
- Water Purifier
- Ultrasonic Cleaner
- Pipette
- Microtome
- Medical Hand Sink
- Medical Freezer
- Blood Bank Refrigerator
- Medical Pharmacy Refrigerator
- Analysis Balance
- Medical Destroyer
- In-Vitro Diagnostics
- Hemodialysis Equipment
- Hospital Furniture
- Walking Aids
- First-Aid Products
- Medical Endoscope
- Medical Human Model
- Ophthalmic Equipment
- Dental Equipment
- ENT Equipment
- Home Care Equipment
- Veterinary Equipment
- Medical Consumables
- Personal Protective Equipment
Features
l Ultrasonic host operating system: Windows operating system.
l carotid artery intima measurement thickness (IMT).
l Automatic spectral envelope measurement.
l Monitor: ≥21.5 inch, high definition ultrasonic display, ≥13.3 inch touch screen.
l Applications: Abdomen, obstetrics, gynecology, heart, urinary system, small organs, superficial, blood vessels, pediatrics, newborns, musculoskeletal.
l Applications and report: Abdominal,OB,GYN,Cardiac,Urinary,Small Parts,Superficial, Vascular, Pediatrics, Advanced measurement software packages, report software packages, case management software packages, etc
Technical Specifications
PARAMETER |
SPECIFICATION |
2D Imaging Mode |
|
Gain |
0-100, Step 1 adjustable |
TGC |
8 segment adjustable |
Dynamic |
30-180, 35 level, step 5 adjustable |
Speckle reduction |
0-5, 5 level |
Space Synthesis |
0-2, 2 level (Liner probe: 3 level, cardiac probe:0) |
Sound power |
2-10, 9 level |
Edge Enhancement |
0-5, 5 level |
Maximum focus point |
≥7, which can be moved throughout the whole process |
Grey scale |
0-67, 67 level |
False color |
0-67, 67 level |
Image style |
Soft-Comparison, 2 level |
Frame correlation |
0-4, 4 level adjustable |
Line density |
low, middle, high, 3 level |
Noise reduction |
0-5, 5 level |
The screen has real-time display of voice power, probe frequency, dynamic range, pseudo color, gray scale and other 11 parameters can be adjusted. |
|
Color Doppler Imaging Mode |
|
Blood gain |
0-100, Step 2 |
Parameter display |
Velocity, Variance |
B-Restrain (B/W restrain) |
0-7, 7 level |
Speed Through |
0-8, 8 level |
Sampling number |
6-24, 7 level |
Blood flow preferred |
0-8, 8 level |
Filtering |
1-6, 6 level |
Sound power |
2-6, 4 level |
Noise reduction |
0-4, 4 level |
Smooth treatment |
0-4, 4 level |
Frame correlation |
0-6, 6 level |
Chromatography (Blood flow graph) |
0-37, 37 level |
Line density |
Low-Middle-High, 3 level |
Frequency |
4 level adjustable |
Velocity |
Minimum 0.4K, Maximum 40.5K |
Convex probe |
0.4K-4.3K-38.5K |
Linear probe |
0.4K-14.7K-39.0K |
Trans-vaginal probe |
0.4K-7.8K-39.7K |
Volume probe |
0.4K-4.2K-34.8K |
Micro-convex probe |
0.4K-10.3K-40.5K |
Cardiac probe |
0.4K-7.8K-39.7K |
PS: The frequency of the probe changes and the frequency value changes |
|
PS: Frame rate changes with speed |
|
Pulse wave Doppler (PW) |
|
Gain |
0-100, Step 2 |
Spectrum envelope function: real time automatic spectrum envelope, manual spectrum envelope, and other modes. The system automatically analyses and displays various data such as PSV, EDV, RI, PI, S/D, ACC, HR and so on. Can wake up or close. |
|
Sample volume |
0.5mm- 30mm |
Blood angel |
-75—75 degree, Step 5 |
False color |
0-67, 67 level |
Dynamic range |
20-40, 4 level |
Filter |
0-9, 9 level |
Smooth treatment |
1-4, 4 level |
Sound power |
2-5, 4 level |
Volume |
0-100, 10 level, Step 10 |
Audio filtering |
0-4, 4 level |
Base line |
-1.0~1.0 |
Grey map |
0-67, 67 level |
Scan velocity |
100-500, 6 level |
PRF |
Minimum 0.5K, Maximum 87.5K |
Convex probe |
0.5K-4.3K-63.3K |
Linear probe |
0.5K-14.5K-78.4K |
Trans-vaginal probe |
0.5K-8.1K-78.4K |
Volume probe |
0.5K-4.2K-53.8K |
Micro-convex probe |
0.5K-10.3K-81.1K |
Cardiac probe |
0.5K-4.3K-87.5K |
Frequency |
4 level |
PS: The frequency of the probe changes and the PRF value changes |
|
PS: The frequency of the probe changes and the frequency value changes |
|
Continuous Wave Doppler (CW) |
|
Support probe |
Cardiac probe |
Adjustment of B mode parameters is switchable |
|
Gain |
0-100, Step 2 |
Sampling line position is adjustable |
|
PRF |
0.9K~36.1K |
Baseline |
-1.0~1.0 |
Blood angel |
-75~75 degree |
Grey map |
0-67 |
Scan velocity |
100-300 |
False color |
0-67 |
Dynamic range |
20-40 |
Filtering |
0-9, 9 level |
Smooth treatment |
1-4 |
Frequency |
2.0MHz/2.3MHz/2.5MHz/3.0MHz, 4 level adjustable |
Sound power |
2-5 |
Volume |
0-100 |
Audio Filtering |
0-4 |
Anatomical M imaging |
|
Support probe |
Convex probe, Linear probe,Cardiac probe |
Adjustment of B mode parameters is switchable |
|
Gain |
0-100, Step 2 |
M Sampling line angel is adjustable |
|
M Sampling line length is adjustable |
|
Sampling line: 3, Can be displayed or hidden separately |
|
Blood flow M mode (MC) |
|
Adjustment of B mode parameters is switchable |
|
Gain |
0-100, Step2 |
MC Sampling line angel is adjustable |
|
MC Sampling line length is adjustable |
|
Frequency |
4 level |
Sampling number |
6-24 |
Speed through |
0-8, 8 level |
Scan velocity |
150-500 |
Frame correlation |
0-6, 6 level |
Filtering |
1-6, 6 level |
Blood flow preferred |
0-8, 8 level |
Smooth treatment |
0-4, 4 level |
Map |
0-37, 37 level |
Elastography |
|
Adjustment of B mode parameters is switchable |
|
Gain |
0-100, Step 2 |
B/E, Double real-time display on the same screen |
|
Probe displacement curve display |
Up/Down |
Pressure indicator bar display |
|
Frequency |
8-9 level, Adjustable; According to the probe display |
Noise reduction |
0-2, 2 level |
Frame correlation |
0-3, 3 level |
Comparison |
0-13, 13 level |
False color |
0-3, 3 level |
Don’t support cardiac probe |
|
Tissue Doppler imaging (TDI) |
|
Support probe |
Cardiac probe |
Adjustment of B mode parameters is switchable |
|
Gain |
0-100, step 2 |
ROI area adjustable |
|
Sampling number |
6-24 |
Velocity |
0.4K-8.0K |
Frame correlation |
0-6, 6 level |
Tissue preferred |
0-7, 7 level |
Frequency |
2.0MHz/2.3MHz/2.5MHz/3.0MHz |
Support color reversal |
|
Strain rate imaging |
|
Support probe |
Cardiac probe |
Adjustment of B mode parameters is switchable |
|
ROI area adjustable |
|
Gain |
0-100, Step 2 |
Sampling number |
6-24, 6 level |
Axial average |
1-4, 4 level |
Velocity |
0.4K-8K |
Frame correlation |
0-6, 6 level |
Tissue optimization |
0-7, 7 level |
Panoramic imaging |
|
Support probe |
Linear probe |
Speckle Reduction |
0-5, 5 level |
Deflection imaging |
|
Support probe |
Linear probe |
Adjustment of B mode parameters is switchable |
|
Deflection angel |
8 level |
Speckle reduction |
0-5, 5 level |
Dynamic rate |
30-180, Step 5 |
Line density |
low-middle-high, 3 level |
Frame Correlation |
0-4, 4 level |
False color |
0-67, 67 level |
Image style |
Soft-Comparison, 2 level |
Noise reduction |
0-5, 5 level |
Edge Enhancement |
0-5, 5 level |
Sound power |
2-10, 8 level |
Grey map |
0-67, 67 level |
Trapezoidal imaging |
|
Probe support |
linear probe |
Adjustment of B mode parameters is switchable |
|
Deflection angel |
8 level |
Speckle reduction |
0-5, 5 level |
Dynamic rate |
30-180, Step 5 |
Line density |
low-middle-high, 3 level |
Frame Correlation |
0-4, 4 level |
False color |
0-67, 67 level |
Image style |
Soft-Comparison, 2 level |
Noise reduction |
0-5, 5 level |
Edge Enhancement |
0-5, 5 level |
Sound power |
2-10, 8 level |
Grey map |
0-67, 67 level |
Space Synthesis |
0-2, 2 level |
Freehand 3D imaging |
|
Support probe |
convex probe, linear probe |
Display model |
4 pictures |
Image Rotation X/Y/Z Axis |
|
Multi-slice Visibility |
|
Real-time 4D imaging |
|
Support probe |
4D volume probe |
Adjustment of B mode parameters is switchable |
|
Gain |
0-100, Step 2 |
Display model |
one image, two images, four images |
Image Rotation: X/Y/Z Axis |
|
Multi-slice Visibility |
|
Light&Shade inversion |
|
Smooth |
0-4, 4 level |
Threshold level |
0-129, Step 3 |
Transparency |
1-509, Step 10 |
Render type |
4 kinds, Surface, maximum, minimum, perspective |
Extended Imaging |
|
Gain |
0-100, Step 2 |
TGC |
8 segment adjustable |
Maximum focus point |
≥7, which can be moved throughout the whole process |
Speckle reduction |
0-5, 5 level |
Space Compound |
0-2, 2 level (Linear probe: 3 level, don’t support cardiac probe) |
Dynamic range |
30-180, 35 level, Step 5 |
Line density |
Low, Middle, High, 3 level |
Frame correlation |
0-4, 4 level |
Noise reduction |
0-5, 5 level |
Edge enhancement |
0-5, 5 level |
Sound power |
2-10, 9 level |
Grey map |
0-67, 67 level |
False color |
0-67, 67 level |
Image style |
Soft-Comparison, 2 level |
Extended level |
Maximum 72 level |
Convex probe |
9 level |
Trans-vaginal probe |
72 level |
Micro-convex probe |
29 level |
Cardiac probe |
40 level |
4D Volume probe |
17 level |
PS: The screen has real-time display of voice power, probe frequency, dynamic range, pseudo color, grayscale and other 11 parameters can be adjusted |
|
PS: When the probe scan range reaches the maximum, the space synthesized is 0. |
Various Probes
l Convex probe
Fundamental Frequency: 2.0MHz/ 2.3MHz/ 2.5MHz/ 3.0MHz/ 3.5MHz/ 4.0MHz/ 4.6MHz/ 5.0MHz/ 5.4MHz
Harmonic Frequency: 4.0MHz/ 4.6MHz/ 5.0MHz
l Linear probe
Fundamental Frequency: 4.0MHz/ 4.6MHz/ 5.0MHz/ 6.0MHz/ 7.0MHz/ 8.0MHz/ 9.2MHz/ 10.0MHz/ 12.0MHz/ 13.3MHz
Harmonic Frequency: 8.0MHz/ 9.2MHz/ 10.0MHz
l Micro-convex probe
Fundamental Frequency: 3.0MHz/ 3.5MHz/ 4.0MHz/ 5.0MHz/ 5.4MHz/ 6.0MHz/ 7.0MHz/ 8.0MHz
Harmonic Frequency: 6.0MHz/ 7.0MHz/ 8.0MHz
l Cardiac probe
Fundamental Frequency: 1.7MHz/ 1.9MHz/ 2.1MHz/ 2.5MHz/ 3.0MHz/ 3.4MHz/ 3.8MHz/ 4.2MHz/ 5.0MHz
Harmonic Frequency: 3.4MHz/ 3.8MHz/ 4.2MHz
l 4D volume probe
Fundamental Frequency: 2.0MHz/ 2.5MHz/ 3.0MHz/ 3.3MHz/ 3.7MHz/ 4.0MHz/ 5.0MHz/ 6.0MHz
Harmonic Frequency: 4.0MHz/ 5.0MHz/ 6.0MHz
l Rectal linear probe
Fundamental Frequency: 4.0MHz/ 4.6MHz/ 5.0MHz/ 6.0MHz/ 7.0MHz/ 8.0MHz/ 9.2MHz/ 10.0MHz/ 12.0MHz/ 13.3MHz
Harmonic Frequency: 8.0MHz/ 9.2MHz/ 10.0MHz
Graphic and Text Management System
l Host build in 2 hard disk (SSD 120+1T), start fast and stable.
l Movie playback: ≥1200 frames.
l Type of report is 16.
l One key fast report graphic and text management.
Internal file information management system: can record patient number, name, check number, check date and so on, and can be searched and managed by numbering, checking number, name and so on