Products

AR-48E/48R

Real-Time PCR Analyzer

Features

The unit is designed to meet the needs of small and medium sized laboratories, mobile laboratories, and on-site testing. With its excellent performance and portability, it can make your experiments more easy-to-use, accurate and efficient.


Technical Specifications

Model

48E

48R

Throughput

48-well

Fluorescence Channels

4

2

Compatible Fluorophores

Channel 1: FAM, SYBR Green I, etc.

Channel 2: VIC, HEX, TET, JOE, etc.

Channel 3: ROX, Texos Red, etc.

Channel 4: Cy5, etc.

Channel 1: FAM, SYBR Green I, etc.

Channel 2: VIC, HEX, TET, JOE, etc.

Light Source

High-brightness, long-life and maintenance-free LED light source

Detector

Photodiodes (PDs)

Fluorescence Scanning Time

48-well 4-color detection

completed within 2s

48-well 2-color detection

completed within 2s

Heating Rate

Maximum heating ramp rate 8.0°C/s;

Average heating ramp rate 6.2°C/s

Cooling Rate

Maximum cooling ramp rate 6.2°C/s;

Average cooling ramp rate 4.5°C/s

Temperature Accuracy

0.1°C

Special Temperature

Setting Function

Support thermal gradients PCR, Long PCR, Touch Down PCR

Suitable Consumables

0.2ml clear non-skirt 48-well plates, 8-tube strips,single tubes,etc.

Sample Testing Linearity

And Repeatability

Linear Correlation: /r/ 0.999

Repeatability: cycle threshold (Ct) value CV 0.5%

Software Analysis

Qualitative analysis, absolute quantitative analysis,relative quantitative analysis, end point fluorescence analysis,melting curve analysis,and genotyping analysis, etc.

Control Method

Stand-alone operation: 7-inch touchscreen control;

Cloud-enabled: PC software control via direct connection or LAN (local area network);

Up to 10 devices controlled by one PC

Power Failure Protection

Automatic recovery of the experiment and other functions when the power is on again after cutting off, without waiting for the power-on of the computer or sofaware control

Date Storage and Transmission

A single machine can store more than 1000 experimental data files, which can be imported and exported via USB disks

Stand-Alone Analysis Results

No need for an extra computerexperimental data analysis enabled within the instrument; Direct printing function (optional) to output the sample α mplification curve and CT value, simply by connecting to the compatible thermal printer

Reporting Function

Built-in experiment report templates for a variety of industries; Fully open universal reporting of which the contents and formats can be customized

Operating System for PC

Windows XP Pro or higher

Power Supply and Power Consumption

AC 100-240V,50-60HZ;600VA

Weight

11Kg

Instrument Dimension

260x400x260mm (WxLxH)


Copyright © 2001-2024 ARI Medical Technology Co., Ltd. - ARI Technology Group Co., Ltd. All Rights Reserved.