Products
-
- Operating Theatre Equipment
- OB/GYN Equipment
- Diagnostic Equipment
- Sterilizer (Autoclave)
- X-ray Series
- Laboratory Equipment
- Biological Microscope
- Spectrophotometer
- High Speed Centrifuge
- Low Speed Centrifuge
- High Speed Freeze Centrifuge
- Low Speed Freeze Centrifuge
- Special Centrifuge
- Thermostatic Bath
- Laboratory Shaker
- Laboratory Mixer
- Water Distiller
- Magnetic and Electric Stirrer
- Laboratory Incubator
- Dry Oven
- PH Meter
- Biological Safety Cabinet
- Clean Workbench
- Water Purifier
- Ultrasonic Cleaner
- Pipette
- Microtome
- Medical Hand Sink
- Medical Freezer
- Blood Bank Refrigerator
- Medical Pharmacy Refrigerator
- Analysis Balance
- Medical Destroyer
- In-Vitro Diagnostics
- Hemodialysis Equipment
- Hospital Furniture
- Walking Aids
- First-Aid Products
- Medical Endoscope
- Medical Human Model
- Ophthalmic Equipment
- Dental Equipment
- ENT Equipment
- Home Care Equipment
- Veterinary Equipment
- Medical Consumables
- Personal Protective Equipment
Introduction
Blood and Infusion Warmer is to warm the blood or fluid and to relieve the patient’s hyperthermia; it is widely used before operation, during operation and after operation and ICU, NICU, Pediatric Dept., Emergency Dept., and Outpatient Dept., for heating blood or infusion. Small design, direct display and simple operation makes it user friendly.
Features
1. Exquisite Workmanship, small design. 0.2 kg weight, more installation method optional
2. Multiple Temperature Control Protection Technology. Hardware and software temperature control protection to ensure the effective and safe heating
3. 2 mins Fast Heating to transfer the heat to the patient
4. Three Heating Groove: Long, middle, short groove to meet different needs
5. High Accuracy: Deviation is within ±1℃
Technical Specifications
MODEL |
AIW-110A |
Temperature setting |
℃: 35.0 - 42.0 ℃ ℉: 95.0 - 107.6 ℉ |
Temperature accuracy |
℃: ≤±1 ℃ ℉: ≤±1.8 ℉ |
Increment |
℃: 0.1 ℃ ℉: 0.2 ℉ |
Optional unit |
℃ / ℉ |
Warming up time |
≤2 min |
Overheat protection |
46 ℃, hardware and software protection |
Alarm |
Over heat, low temperature, system error, door open, warming up alarm |
Blood and IV sets |
Standard single used PVC blood or IV tubes (diameter: 3.4-4.5 mm) |
Display |
LED |
Heating method |
Long, Middle, Short grooves |
Installation method |
IV knob, Hanger optional |
Power supply |
Input: 100-240 V (AC power), 50/60 Hz, 0.3-0.7 A Output: 12 V (DC power, 2.5 A |
Power consumption |
85 VA |
Operation environment |
Temperature: 5-30 ℃ Humidity: 20-80 % Atmosphere: 76.0-106.0 kPa |
Transportation and storage environment |
Temperature: -20 - 55 ℃ Humidity: 10-93 % Atmosphere: 50.0-106.0 kPa |
Protection class |
Class II, Type CF, IPX1 |
Working mode |
Continuous heating |
Dimension |
180*70*35 mm |
Weight |
0.2 kg With knob: 0.4 kg |