Products
-
- Operating Theatre Equipment
- OB/GYN Equipment
- Diagnostic Equipment
- Sterilizer (Autoclave)
- X-ray Series
- Laboratory Equipment
- Biological Microscope
- Spectrophotometer
- High Speed Centrifuge
- Low Speed Centrifuge
- High Speed Freeze Centrifuge
- Low Speed Freeze Centrifuge
- Special Centrifuge
- Thermostatic Bath
- Laboratory Shaker
- Laboratory Mixer
- Water Distiller
- Magnetic and Electric Stirrer
- Laboratory Incubator
- Dry Oven
- PH Meter
- Biological Safety Cabinet
- Clean Workbench
- Water Purifier
- Ultrasonic Cleaner
- Pipette
- Microtome
- Medical Hand Sink
- Medical Freezer
- Blood Bank Refrigerator
- Medical Pharmacy Refrigerator
- Analysis Balance
- Medical Destroyer
- In-Vitro Diagnostics
- Hemodialysis Equipment
- Hospital Furniture
- Walking Aids
- First-Aid Products
- Medical Endoscope
- Medical Human Model
- Ophthalmic Equipment
- Dental Equipment
- ENT Equipment
- Home Care Equipment
- Veterinary Equipment
- Medical Consumables
- Personal Protective Equipment
Features
l All parts of the system are fully controlled and monitored by Microprocessor Technology:
l Smoothly and efficiently controlling. the emulsifier process with digital frequency tracing technology of handpiece.
l Easy operation and user-friendly interface with large touch screen TFT and functional menu.
l Up to 10 sets of parameters preset meets different requirements and simplifies the surgery operation.
l Auto test checks tubing and handpiece problems (e.g.: block or leakage).
l The peristaltic pump gives complete control of aspiration flow rate as well as freedom from anterior chamber shallowing. This way can give stronger suction when working in l/A
l Built-in vitrectomy and cautery.
l Intelligent voice reminder.
Technical Specifications
Parameter |
Specifications |
Ultrasonic Emulsification(U/S) |
|
Frequency |
40kHz |
Functional mode |
Continuance, Pulse, Linear and Burst |
Continuance |
Emulsifying Power Range 0~100% |
Pulse |
Frequency Range 1~99Hz |
Linear |
Emulsifying Power Linearly controlled by Foot Switch, varies between 0~100% |
Burst-Stopping Time |
1.5~0s |
Working Time |
5~100ms |
Maximum Vacuum |
500 mmHg |
Maximum Flux Rate |
40 ml/min |
Lrrigation /Aspiration(l/A) |
|
Flux Rate |
0~40 ml/min |
Reflux Rate |
20 ml/min |
Max Vacuum |
500 mmHg |
Vitrectomy(VIT) |
|
Cutting Power Source |
Air Pump |
Cutting Frequency |
20~600/min; Single Cut Mode |
Maximum Vacuum |
500 mmHg |
Maximum Flux Rate |
40 ml/min |
Cautery |
|
Maximum Power |
10 w + 20%(200Ω) |
Type |
Bipolar |
Power preset between |