Products
-
- Operating Theatre Equipment
- OB/GYN Equipment
- Diagnostic Equipment
- Sterilizer (Autoclave)
- X-ray Series
- Laboratory Equipment
- Biological Microscope
- Spectrophotometer
- High Speed Centrifuge
- Low Speed Centrifuge
- High Speed Freeze Centrifuge
- Low Speed Freeze Centrifuge
- Special Centrifuge
- Thermostatic Bath
- Laboratory Shaker
- Laboratory Mixer
- Water Distiller
- Magnetic and Electric Stirrer
- Laboratory Incubator
- Dry Oven
- PH Meter
- Biological Safety Cabinet
- Clean Workbench
- Water Purifier
- Ultrasonic Cleaner
- Pipette
- Microtome
- Medical Hand Sink
- Medical Freezer
- Blood Bank Refrigerator
- Medical Pharmacy Refrigerator
- Analysis Balance
- Medical Destroyer
- In-Vitro Diagnostics
- Hemodialysis Equipment
- Hospital Furniture
- Walking Aids
- First-Aid Products
- Medical Endoscope
- Medical Human Model
- Ophthalmic Equipment
- Dental Equipment
- ENT Equipment
- Home Care Equipment
- Veterinary Equipment
- Medical Consumables
- Personal Protective Equipment
Introduction
Digital X-ray Radiography System adopts floor-mounted table and wall stands. It is a high-end digital radiography device with wide range of applications, which could perform routine imaging of human head, chest, abdomen, lumbar vertebra and limbs with PA, LAT and clinostatism in hospitals at all levels. Its smart design, flexible movement, easy operation and high working efficiency provide more imaging positions.
Features
1. High frequency generator with high X-ray inverse frequency, large power and good X-ray quality.
2. Sophisticated technology, high rotating speed, good heat dissipation, high heat capacity, suitable for long-time clinical examination, long product life.
3. Smart high voltage control system with various APR.
4. High level image acquisition system provides more post-processing and meets clinical needs.
5. New generation a-Si Csl flat panel detector with high conversion rate achieves digital image acquisition with low dose.
Technical Specifications
Model |
ARQ-32 |
ARQ-50 |
ARQ-65 |
ARQ-80 |
|||||||||||||||||||||
X-Ray Tube |
|||||||||||||||||||||||||
Anode type |
Rotating Anode |
||||||||||||||||||||||||
Focal Spot value |
1.0mm /2.0mm |
0.6mm /1.2mm |
0.6mm /1.2mm |
0.6mm /1.2mm |
|||||||||||||||||||||
Maximum voltage |
125KV |
150KV |
150KV |
150KV |
|||||||||||||||||||||
Revolving speed of anode |
2800rpm |
||||||||||||||||||||||||
Inherent filtration |
1.0mmAl |
||||||||||||||||||||||||
Anode heat storage capacity |
150kHU |
300kHU |
300kHU |
300kHU |
|||||||||||||||||||||
Maximum cooling rate of anode |
410W |
750W |
750W |
750W |
|||||||||||||||||||||
Housing heat storage capacity |
900kJ |
||||||||||||||||||||||||
X-ray Generator |
|||||||||||||||||||||||||
Power Output |
32KW |
50KW |
65KW |
80KW |
|||||||||||||||||||||
Power Input |
Standard 380V 3 Phase. Optional 220V or 110V Single Phase Transformer |
||||||||||||||||||||||||
Frequency |
≥25KHZ |
||||||||||||||||||||||||
Current |
10-400mA |
10-630mA |
10-800mA |
10-1000mA |
|||||||||||||||||||||
Voltage |
40kv-150kv |
||||||||||||||||||||||||
mAs |
0.1-400mAs |
0.1-630mAs |
0.1-800mAs |
0.1-1000mAs |
|||||||||||||||||||||
Exposure time |
1-6300ms |
||||||||||||||||||||||||
APR program |
Equipped |
||||||||||||||||||||||||
Intelligent protection system |
It has self-protection system. It will give an alarm and check fault code |
||||||||||||||||||||||||
Flat Panel Detector |
|||||||||||||||||||||||||
Type |
Amorphous Silicon |
||||||||||||||||||||||||
Scintillator |
Cesium Iodide |
||||||||||||||||||||||||
Vision size |
17*17" (43cmx43cm) |
||||||||||||||||||||||||
Active pixel |
3072 x 3072 |
||||||||||||||||||||||||
Pixel pitch |
139um |
||||||||||||||||||||||||
A/D conversion |
16bits |
||||||||||||||||||||||||
Spatial resolution |
3.6Lp/mm |
||||||||||||||||||||||||
Acquisition time |
≤1S |
||||||||||||||||||||||||
Grid |
|||||||||||||||||||||||||
Densities |
103 L/INCH |
||||||||||||||||||||||||
Ratios |
10:1 |
||||||||||||||||||||||||
Size |
18”×18” |
||||||||||||||||||||||||
Focal distance |
180 cm |
||||||||||||||||||||||||
Table |
|||||||||||||||||||||||||
Type |
Radiography Table |
||||||||||||||||||||||||
Tabletop size |
2200mm×1040mm |
||||||||||||||||||||||||
load-bearing |
≥150KG |
||||||||||||||||||||||||
Collimator |
|||||||||||||||||||||||||
Type |
Manual Collimator |
||||||||||||||||||||||||
Max.window |
350mm×350mm (SID=65cm) |
||||||||||||||||||||||||
Min.window |
50mm×50mm (SID=100cm) |
||||||||||||||||||||||||
Lamp |
12~24V AC, DC 2A, 1A |
||||||||||||||||||||||||
Lamp timer |
Automatic illumination with timer for lamp(35S) |
||||||||||||||||||||||||
Inherent filtration |
1.5mmAl |
||||||||||||||||||||||||
Illuminant |
LED |
||||||||||||||||||||||||
Movement |
|||||||||||||||||||||||||
1.Tube Stand |
|||||||||||||||||||||||||
Up-down movement |
≥1100mm |
||||||||||||||||||||||||
Stand left-right movement |
≥1300mm |
||||||||||||||||||||||||
Rotational angles of stand |
+180°~-180° |
||||||||||||||||||||||||
Rotational angles of tube |
360° |
||||||||||||||||||||||||
2.Detector Stand |
|||||||||||||||||||||||||
Up-down movement |
≥1100mm |