Products
-
- Operating Theatre Equipment
- OB/GYN Equipment
- Diagnostic Equipment
- Sterilizer (Autoclave)
- X-ray Series
- Laboratory Equipment
- Biological Microscope
- Spectrophotometer
- High Speed Centrifuge
- Low Speed Centrifuge
- High Speed Freeze Centrifuge
- Low Speed Freeze Centrifuge
- Special Centrifuge
- Thermostatic Bath
- Laboratory Shaker
- Laboratory Mixer
- Water Distiller
- Magnetic and Electric Stirrer
- Laboratory Incubator
- Dry Oven
- PH Meter
- Biological Safety Cabinet
- Clean Workbench
- Water Purifier
- Ultrasonic Cleaner
- Pipette
- Microtome
- Medical Hand Sink
- Medical Freezer
- Blood Bank Refrigerator
- Medical Pharmacy Refrigerator
- Analysis Balance
- Medical Destroyer
- In-Vitro Diagnostics
- Hemodialysis Equipment
- Hospital Furniture
- Walking Aids
- First-Aid Products
- Medical Endoscope
- Medical Human Model
- Ophthalmic Equipment
- Dental Equipment
- ENT Equipment
- Home Care Equipment
- Veterinary Equipment
- Medical Consumables
- Personal Protective Equipment
Product Description
Accurate Principle of
Methodology
Adopts classical and accurate principle of methodology – Ion exchange liquid
chromatography, It is the gold standard of HbA1C analysis, and it is the only
analysis method to really separate HbA1C directly by measuring the piecemeal
absorbance through continuous test on line, and obtain the correct area
percentage with integration.
●Accurate separation
4-gradient elution
The novel 4-gradient elution for HbA1C can separate accurately glycated
hemoglobin with 4-gradient elution of corresponding concentration reagent
aiming at HbA1C instead of routine elution process produced by high and low
concentration mixture.
●High Separation Liquid Chromatographic Column
High separation liquid chromatographic column made of imported resin with
volume of Φ 9mm x 45mm and weight of 2.5g which is 15 – 20 times greater than
general micro chromatographic column. High efficiency chromatographic column
for 300 tests ensure the accuracy of test results.
●High Sensitivity 415nm LED Integral Photometer
High sensitivity 415nm LED integral photometer has the characteristics of
correct wavelength, stable light source, full aluminum alloy structure, high
anti-interference performance, multi-lens focusing, micro cuvettes and high
sensitivity. It can record accurately analysis curve.
●Supply with Original Calibrator
The international standard value tracing is adopted. The authoritative
reference material for quality control is used to transfer the numeric value.
Each set of reagent is supplied with two sets of calibrator for proper
calibration so as to ensure that the test results are correct and reliable and
thoroughly to avoid individual error caused by factor calibration.
●Precision Chromatographic Column and Thermostatic Apparatus
Precision chromatographic column and reagent thermostatic control apparatus
ensure that Chromatographic column and reagent are not affected by environment
temperature and effectively guarantees the repeatability and correctness of the
test results.
●Real-time summarized
chromatogram, Intelligence process detection
The advanced embedded micro processing system + intelligence control software
can really display testing curve and the real redisplay of testing process and
can monitor and alarm for test results, absorbency, signal potential, peak time
and reagent consumption. It can be operated with high proficiency.
●Full-auto 25-position Sample Turntable, Optional Selection of Batch Test or
Emergency Test With full-auto 25-position sample turntable, it is unnecessary
to use complicated rank sampling device and built-in hemolysis device. Batch
test can be automatically carried out. Emergency test can be carried out at any
time.
●Full-open Structure, perfect flow path, low failure and easy maintenance
Full-open structure, Perfect solenoid valve flow path, it is unnecessary to use
complicated sample mechanical 6-way and rotating distribution control valve. It
is reliable for use and easy for maintenance.
●5ul whole blood, for both labs and clinics
5ul whole blood, both venous blood and peripheral finger blood can be tested,
suitable for labs for batch tests and also suitable for clinics for providing
test results immediately. Both venous blood and peripheral finger blood can be
tested.
●With gas solution and bubble-removal technology, the error can be eliminated
overall.
Since the instrument is equipped with reagent solvability gas eliminating
device and applies the cuvette bubble auto detection eliminating technology,
the air bubbles which affect the test results can be eliminated overall without
the complicated degassing device.
●Saccharification concentration, area percentage and average glucose can be
synchronously reported.
The instrument can output the data including IFCC concentration value, NGSP area
percentage and ADAG average glucose on the test report synchronously to meet
the requirement of world standardization. It may memorize 1000 test curve
reports and is equipped with RS232 communication interface and can connect
directly to HIS/LIS system.
Specifications
Model |
AC6601 Full-auto glycated hemoglobin HbA1c Analyzer |
Basic Parameters |
|
Testing Method |
Low pressure ion exchange liquid chromatography |
Testing Item |
glycated hemoglobin HbA1c |
Testing Scope |
3% ~ 18% |
Testing Parameters |
Precision (CV) ≤3%, Accuracy (V) ≤1.50% |
Testing Time |
4 minutes (including reporting) |
Sample type |
venous blood (EDTA anticoagulation),Peripheral finger blood |
Sample volume |
5μl whole blood for each sample |
Functional Parameters |
|
Photometer |
415nm LED Integral flow colorimeter |
Sampling mode |
Full-auto 25-position sample turntable (20 sample positions, 2 quality control positions, 1 emergency position, 1 cleaning position, 1 zero position) |
Testing mode |
auto test for batch, single test for emergency |
Calibration |
Optional selection of 2 points or 4 points calibration, optional selection of manual or automation, Equipped with 2 groups of high and low level calibrators |
Thermostatic control |
Column and reagent thermostatic control: 25 ± 0.5℃ |
Reagent matching |
one piece of column and reagent consumable/300 pieces of testing samples |
Reagent allocation |
Each standard package includes A, B, C, D eluent, calibrator, hemolytic agent, pump tubing |
Output Parameters |
|
Display |
320x240 LCD Graphic Display, displaying real-time testing curve |
Printer |
58mm Thermal printer, printing testing curve and report |
Report Output |
IFCC concentration value, NGSP area percentage, ADAG average glucose |
Data storage |
1000 test report (including testing curve) |
Communication interface |
RS232 communication interface, connecting to HIS/LIS system |
Working Parameters |
|
Power Supply |
AC220V±22V 50Hz 215VA |
size |
408mm×390mm×230mm |
Weight |
9kg |
Working Environment |
Temperature 12℃-30℃,Relative humidity ≤85% |